User`s manual
Compliance Certification Services Inc.
Report No:T11112830801-LV
Page 28 of 72
2.2.3 TABLE : SELV measurement (under fault conditions)
N
Location Voltage measured (V) Comments
--
Note :
2.4.2 TABLE : limited current circuit measurement
N
Location Voltage
(V)
Current
(mA)
Freq.
(kHz)
Limit
(mA)
Comments
--
Note :
2.5 TABLE : limited power source measurement
P
Limits Measured Verdict
According to Table 2B (Normal conditions) : USB1, USB port, Uoc=4.975V
Current (in A) ≤8.0 2.824 Pass
Power (in VA) ≤100 10.90 Pass
According to Table 2B (Single fault conditions) : USB1, USB port, Uoc=4.950V, Q1pin3 to pin2 short.
Current (in A) ≤8.0 2.942 Pass
Power (in VA) ≤100 12.48 Pass
According to Table 2B (Normal conditions) : PHJ1 (all pins), All RJ-45 port, Uoc=0V
Current (in A) ≤8.0 0 Pass
Power (in VA) ≤100 0 Pass
Note :
2.10.2 TABLE : Working voltage measurement
N
Location Peak voltage (V) RMS voltage (V) Comments
--
Note :
2.10.3 and 2.10.4 TABLE: Clearance and creepage distance measurements
N
Clearance (cl) and creepage
distance (cr) at/of/between:
U peak
(V)
U r.m.s.
(V)
Required cl
(mm)
cl
(mm)
Required cr
(mm)
cr
(mm)
--
Note :
2.10.5 TABLE: Distance through insulation measurements
N
Distance through insulation (DTI) at/of: U peak
(V)
U rms
(V)
Test
voltage
(V)
Required DTI
(mm)
DTI
(mm)
--
Supplementary information: