User`s manual
Compliance Certification Services Inc.
Report No:T11112830801-LV
Page27 of 72
1.5.1 TABLE: List of critical components
P
Object/part No. Manufacturer/
trademark
Type/model Technical data Standard
(Edition / year)
Mark(s) of
conformity
1
)
Plastic
Enclosure
Various Various HB or better,
thickness min.
1.6 mm.
UL 94 UL
Power Adaptor Shenzhen
Jiakeyuan
Industry Co.,
Ltd.
JKY36-
SP1201000
I/P : AC 100-
240V, 50/60Hz,
0.5A max, O/P :
12Vdc, 1.0A,
Class II, LPS,
+25
℃
EN 60950-1:
2006+A11:2009
+A1:2010+A12:
2011
LVD (issued by
Guangzhou ITL Co.,
Ltd. report No.
12011280)
All PCBs
material
-- -- V-1 or better ,
105°C min.
UL 796
UL
1
) An asterisk indicates a mark which assures the agreed level of surveillance
Supplementary information:
1.6.2 TABLE: Electrical data (in normal conditions)
P
U (Vdc) I (A) Irated (A) P (W) Fuse # Ifuse (A) Condition/status
12 0.38 1.0 4.56 -- -- Maximum normal load.
Supplementary information:
The unit operated under all connectors connected and transmit data continuously and USB port connector
with a dummy load of 2.5W to represent the USB load.
2.1.1.5 TABLE: max. V, A, VA test
N
Voltage (rated)
(V)
Current (rated)
(A)
Voltage (max.)
(V)
Current (max.)
(A)
VA (max.)
(VA)
--
Supplementary information :
2.1.1.7 TABLE : discharge test
N
Location
τ calculated
(S)
τ measured
(S)
t u → 0V
(S)
Comments
--
Supplementary information :
2.2.2 TABLE : SELV measurement (under normal conditions)
N
max. voltage Component Location
V peak V rms
Voltage limitation
component
--
Note :