Compliance Certification Services Inc.
Report No:T11112830801-LV
IEC/EN 60950-1
Clause Requirement - Test Result - Remark
Verdict
Page 19 of 72
5.2 Electric strength
Class III equipment.
N
5.2.1 General N
5.2.2 Test procedure N
5.3 Abnormal operating and fault conditions
P
5.3.1 Protection against overload and abnormal
operation
Ventilation opening blocked.
(see appended table 5.3)
P
5.3.2 Motors No motors N
5.3.3 Transformers No transformers. N
5.3.4 Functional insulation Method c) considered. Components
mounted on V-1 material.
P
5.3.5 Electromechanical components No electromechanical components. N
5.3.6 Audio amplifiers in ITE No such parts. N
5.3.7 Simulation of faults (see appended table 5.3) P
5.3.8 Unattended equipment No thermostat, temperature limiter or
thermal cut-off.
N
5.3.9 Compliance criteria for abnormal operating and
fault conditions
See clause 5.3.4 P
5.3.9.1 During the tests No fire, no emit and no shrinkage,
distortion or loosening if any enclosure
part was noticeable on the equipment.
P
5.3.9.2 After the tests P
6 CONNECTION TO TELECOMMUNICATION NETWORKS N
6.1 Protection of telecommunication network service persons, and users of other equipment
connected to the network, from hazards in the equipment.
N
6.1.1 Protection from hazardous voltages No TNV circuit. N
6.1.2 Separation of the telecommunication network
from earth
N
6.1.2.1 Requirements N
Supply voltage (V)
─
Current in the test circuit (mA)
─
6.1.2.2 Exclusions N
6.2 Protection of equipment users from overvoltages on telecommunication networks
N
6.2.1 Separation requirements No TNV circuit.
N
6.2.2 Electric strength test procedure
N
6.2.2.1 Impulse test
N
6.2.2.2 Steady-state test
N
6.2.2.3 Compliance criteria
N
6.3 Protection of telecommunication wiring system from overheating
N
Max. output current (A)
─