User`s manual
Compliance Certification Services Inc.
Report No:T11112830801-LV
IEC/EN 60950-1
Clause Requirement - Test Result - Remark
Verdict
Page 18 of 72
4.7.3.4 Materials for components and other parts inside
fire enclosures.
Internal components except small parts
are V-2 or better.
P
4.7.3.5 Materials for air filter assemblies No air filter assemblies N
4.7.3.6 Materials used in high-components No high voltage components. N
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
5.1 Touch current and protective conductor current
Class III equipment and no TNV circuit.
N
5.1.1 General N
5.1.2 Configuration of equipment under test (EUT) N
5.1.2.1 Single connection to an a.c. mains supply N
5.1.2.2 Redundant multiple connections to an a.c.
mains supply
N
5.1.2.3 Simultaneous multiple connections to an a.c.
mains supply
N
5.1.3 Test circuit N
5.1.4 Application of measuring instrument N
5.1.5 Test procedure N
5.1.6 Test measurements N
Supply voltage (V)
--
Measured touch current (mA)
--
Max. allowed touch current (mA)
--
Measured protective conductor current (mA)
--
Max. allowed protective conductor current (mA)
--
5.1.7 Equipment with touch current exceeding 3.5
mA
N
5.1.7.1 General
N
5.1.7.2 Simultaneous multiple connections to the
supply
N
5.1.8 Touch currents to telecommunication networks
and cable distribution systems and from
telecommunication networks
N
5.1.8.1 Limitation of the touch current to a
telecommunication network or to a cable
distribution system
N
Supply voltage (V)
--
Measured touch current (mA)
--
Max. allowed touch current (mA)
--
5.1.8.2 Summation of touch current from
telecommunication networks
N
a)EUT with earthed telecommunication ports
--
b)EUT whose telecommunication ports have no
reference to protective earth
--