User`s manual
Compliance Certification Services Inc.
Report No:T11112830801-LV
IEC/EN 60950-1
Clause Requirement - Test Result - Remark
Verdict
Page 15 of 72
4.2.3 Steady force test, 30N N
4.2.4 Steady force test, 250N Class III equipment.
N
4.2.5 Impact test Class III equipment. N
Fall test
N
Swing test
N
4.2.6 Drop test Movable equipment.
N
4.2.7 Stress relief Class III equipment.
N
4.2.8 Cathode ray tubes No cathode ray tubes
--
Picture tube separately certified
N
Picture tubes > 16 cm intrinsically protected
N
Non-intrinsically protected tubes > 16 m used
with protective screen
N
Intrinsically protected tubes : tests on 12
samples
N
Samples subject to ageing : 6
N
Samples subject to implosion test : 6
N
Samples subject to mechanical strength test
(steel ball) : 6
N
Non-intrinsically protected tubes tested
N
4.2.9 High pressure lamps No high pressure lamp.
N
4.2.10 Wall or ceiling mounted equipment The equipment and its associated
mounting means shall remain secure
during test. 0.20kg x 3=0.60kg
(3 times weight of equipment)
P
force (N) 50N/1min
--
4.2.11 Rotating solid media No such device.
N
Test to cover on the door
--
4.3 Design and construction
P
4.3.1 Edges and corners All edges and corners judged to be
sufficiently well rounded.
P
4.3.2 Handles and manual controls; force (N) No such controls. N
4.3.3 Adjustable controls No adjustable controls. N
4.3.4 Securing of parts No loosening of parts impairing clearance
or creepage distance is likely to occur.
P
4.3.5 Connection of plugs and sockets IEC60083 and IEC60320 connectors are
not used in equipment.
N
4.3.6 Direct plug-In equipment No direct plug-In equipment. N
Torque N
Compliance with the relevant mains plug
standard
N
4.3.7 Heating elements in earthed equipment No heating elements. N
4.3.8 Batteries No battery. N
-Overcharging of a rechargeable battery N