User`s manual
Compliance Certification Services Inc.
Report No:T11112830801-LV
IEC/EN 60950-1
Clause Requirement - Test Result - Remark
Verdict
Page 9 of 72
b) Impedance limited output (see appended table 2.5)
P
c) Regulating network limited output under
normal operating and single fault condition
(see appended table 2.5)
P
d) Overcurrent protective device limited output
N
Max. output voltage (V), max. output current
(A), max. apparent power (VA)
(see appended table 2.5)
P
Current rating of overcurrent protective device
(A)
No overcurrent protective device.
N
Use of integrated circuit (IC) current limiters No such parts.
N
2.6 Provisions for earthing and bonding N
2.6.1 Protective earthing Class III equipment. N
2.6.2 Functional earthing N
2.6.3 Protective earthing and protective bonding
conductors
N
2.6.3.1 General N
2.6.3.2 Size of protective earthing conductors N
Rated current (A), cross-sectional area (mm
²
),
AWG
─
2.6.3.3 Size of protective bonding conductors N
Rated current (A), cross-sectional area (mm
²
),
AWG
─
2.6.3.4 Resistance of earthing conductors and their
terminations, resistance (
Ω
), voltage drop (V),
test current (A), duration (min)
N
2.6.3.5 Colour of insulation N
2.6.4 Terminals N
2.6.4.1 General N
2.6.4.2 Protective earthing and bonding terminals N
Rated current (A), type nominal thread diameter
(mm)
─
2.6.4.3 Separation of the protective earthing conductor
from protective bonding conductors
N
2.6.5 Integrity of protective earthing N
2.6.5.1 Interconnection of equipment N
2.6.5.2 Components in protective earthing conductors
and protective bonding conductors
N
2.6.5.3 Disconnection of protective earth N
2.6.5.4 Parts that can be removed by an operator N
2.6.5.5 Parts removed during servicing N
2.6.5.6 Corrosion resistance N
2.6.5.7 Screws for protective bonding N
2.6.5.8 Reliance on telecommunication network or
cable distribution system
No telecommunication network. N