User`s manual

Reference No: T110908403-RT
Reference No: 90522403-RT
Report No: T11112830801-RT
Page 13 / 45 Rev.01
8. APPLICABLE LIMITS AND TEST RESULTS
8.1 EQUIVALENT ISOTROPIC RADIATED POWER
LIMIT
EN 300 328 Clause 4.3.1
The equivalent isotropic radiated power shall be equal to or less than -10 dBW (100
mW) e.i.r.p. This limit shall apply for any combination of power level and intended
antenna assembly.
TEST EQUIPMENTS
Name of
Equipment
Manufacturer Model Serial Number Calibration Due
Temp./Humidity
Chamber
K.SON THS-M1 242 AUG. 09, 2012
Power Meter Anritsu
ML2487A 6K00003888 MAY 30, 2012
TEST SETUP
TEST PROCEDURE
1.
.Please refer to ETSI EN 300 328 (V1.6.1) clause 5.3 for the test conditions.
2. Please refer to ETSI EN 300 328 (V1.7.1) clause 5.7.2.2 for the measurement
method.
TEST RESULTS
No non-compliance noted
Variable power supply
Power Meter
EUT
Temperature Chamber