6. CALIBRATION AND UNCERTAINTY
6.1 MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report
has been calibrated in accordance with the manufacturer’s recommendations, and
is traceable to recognized national standards.
6.2 MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated
for tests performed on the apparatus:
Parameter Uncertainty
Radio Frequency ±0.523 x 10-5
Total RF power, conducted ±1.3dB
RF power density, conducted ±2.5dB
Spurious emissions, conducted ±2.6dB
All emissions, radiated ±4dB
Temperature ±1℃
Humidity ±3.2%
DC and low frequency voltages ±1.8%
Uncertainty figures are valid to a confidence level of 95%, k=2