Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT ETSI EN 300 328 TEST REPORT For Smart 300N Broadband Router Model: BR485d Brand : E-TOP Issued for E-Top Network Technology Inc. No. 82 ,Gongye 2nd Rd.,Tainan City 70955,Taiwan, R.O.C. Issued by Compliance Certification Services Inc. Tainan Lab. No.8,Jiucengling, Xinhua Dist., Tainan City 712, Taiwan (R.O.C.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Revision History Rev. Issue Date Revisions Effect Page Revised By 00 February 08, 2012 Initial Issue ALL Sunny Chang Page 2 / 45 Rev.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT TABLE OF CONTENTS 1. TEST REPORT CERTIFICATION.................................................................... 4 2. EUT DESCRIPTION......................................................................................... 5 3. DESCRIPTION OF TEST MODES................................................................... 7 4. TEST METHODOLOGY..............................................................................
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT 1. TEST REPORT CERTIFICATION Applicant Address : : Manufacture Address : : Equipment Under Test : Model Number : Brand Name : Date of Test : E-Top Network Technology Inc. No. 82 ,Gongye 2nd Rd.,Tainan City 70955,Taiwan, R.O.C. E-Top Network Technology Inc. No. 82 ,Gongye 2nd Rd.,Tainan City 70955,Taiwan, R.O.C.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT 2. EUT DESCRIPTION Product Name Smart 300N Broadband Router Model Number BR485d Brand E-TOP Received Date November 28, 2011 Frequency Range IEEE 802.11b/g ,802.11n HT20:2412MHz ~ 2472MHz IEEE 802.11n HT40:2422MHz ~ 2462MHz IEEE 802.11b: 18.71 dBm IEEE 802.11g: 18.34 dBm IEEE 802.11n HT20: 18.23 dBm IEEE 802.11n HT40: 18.40 dBm IEEE 802.11b/g, 802.11n HT20/HT40: 5MHz IEEE 802.11b/g, 802.11n HT20:13 Channels IEEE 802.
Report No: T11112830801-RT Multiple listing: Page 6 / 45 Rev.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT 3. DESCRIPTION OF TEST MODES The EUT is a 11n router. It has two transmitter chains and two receiver chains (2x2 configurations). The 2x2 configuration is implemented with two outside chains (Chain 0 and Chain 1). The RF chipset is manufactured by Realtek Semiconductor Corp. The antenna peak gain 3dBi (highest gain) were chosen for full testing. IEEE 802.11 b ,802.11g ,802.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT 4. TEST METHODOLOGY The tests documented in this report were performed in accordance with ETSI EN 300 328 V1.7.1 : 2006 – Electromagnetic compatibility and Radio spectrum Matters (ERM) ; wideband transmission systems; data transmission equipment operating in the 2.4GHz ISM band and using spread spectrum modulation techniques: Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive. 5.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT 5.3 LABORATORY ACCREDITATIONS LISTINGS The test facilities used to perform radiated and conducted emissions tests are accredited by Taiwan Accreditation Foundation for the specific scope of accreditation under Lab Code: 1109 to perform Electromagnetic Interference tests according to FCC PART 15 AND CISPR 22 requirements.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT 6. CALIBRATION AND UNCERTAINTY 6.1 MEASURING INSTRUMENT CALIBRATION The measuring equipment utilized to perform the tests documented in this report has been calibrated in accordance with the manufacturer’s recommendations, and is traceable to recognized national standards. 6.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT 7. SETUP OF EQUIPMENT UNDER TEST 7.1 SETUP CONFIGURATION OF EUT A B Adapter EUT NoteBook (1) 7.2 SUPPORT EQUIPMENT No. Product 1 Note Book Manufacturer Model No. Certify No. IBM T43 DoC Signal cable Power cable, unshd, 1.6m No. Signal cable description A DC Power Unshielded, 1.2m, 1pcs B LAN Cable Unshielded, 1.0m, 1pcs Remark: 1.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT 7.3 EUT OPERATING CONDITION RF Setup 1. Set up all computers like the setup diagram. 2. Reset equipment and burn in the test program “MP_Test”. 3. The “Realtek Test Program for “RTL819x ” software was used for testing The EUT driver software installed in the host support equipment during testing was Realtek Test Program for RTL819x Drive (1)TX Mode: Ö IC Type: RTL_8192D Ö Mode:2.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT 8. APPLICABLE LIMITS AND TEST RESULTS 8.1 EQUIVALENT ISOTROPIC RADIATED POWER LIMIT EN 300 328 Clause 4.3.1 The equivalent isotropic radiated power shall be equal to or less than -10 dBW (100 mW) e.i.r.p. This limit shall apply for any combination of power level and intended antenna assembly. TEST EQUIPMENTS Name of Equipment Manufacturer Model Temp./Humidity Chamber K.SON THS-M1 242 AUG.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Product Name Model Test Mode Duty Cycle measurement X: 10 * log (1/x) = Antenna Assembly Gain: Cable Loss= TEST CONDITIONS CHANNEL Voltage Middle High (Ton/Ton + Toff) = 2011/12/15 Agun Huang 22℃,51% 1.00 dB dBi dB 0.00 3 0.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Product Name Model Test Mode Duty Cycle measurement X: 10 * log (1/x) = Antenna Assembly Gain: Cable Loss= TEST CONDITIONS CHANNEL Voltage Middle High (Ton/Ton + Toff) = 2011/12/15 Agun Huang 22℃,51% 1.00 dB dBi dB 0.00 3 0.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Product Name Model Test Mode Smart 300N Broadband Router BR485d IEEE 802.11HT20 Duty Cycle measurement X: 10 * log (1/x) = Antenna Assembly Gain: Cable Loss= TEST CONDITIONS CHANN Voltage EL Power Measured Power Low EIRP Middle Measured Power EIRP High Measured Power EIRP Test Date Test By TEMP& Humidity (Ton/Ton + Toff) = 2011/12/15 Agun Huang 22℃,51% 1.00 dB dBi dB 0.00 3 0.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Product Name Model Test Mode Duty Cycle measurement X: 10 * log (1/x) = Antenna Assembly Gain: Cable Loss= TEST CONDITIONS Low EIRP Middle Measured Power EIRP High Measured Power EIRP (Ton/Ton + Toff) = 2011/12/15 Agun Huang 22℃,51% 1.00 dB dBi dB 0.00 3 0.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT 8.2 MAXIMUM SPECTRAL POWER DENSITY LIMIT EN 300 328 Clause 4.3.2.2 For wide band modulations other then FHSS (e.g. DSSS, OFDM, etc.), the maximum spectrum power density is limited to 10 mW per MHz e.i.r.p. TEST EQUIPMENTS Name of Equipment Manufacturer Model Temp./Humidity Chamber K.SON THS-M1 242 AUG.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Product Name Model Mode TEST CONDITIONS Low (dBm/MHz) Measured Power Density Mid (dBm/MHz) High (dBm/MHz) Smart 300N Broadband Router BR485d IEEE 802.11b Measured Power Density Antenna Reading Gain (A) Chain 0 (B) 2011/12/15 Test Date Agun Huang Test By TEMP & Humidity 22℃,51% 10*log (1/x) (C) Cable loss (D) 0.49 0.42 4.99 3.00 0.00 1.50 Limit 10 dBm / MHz +1.5dB / -1.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Product Name Model Mode TEST CONDITIONS Low (dBm/MHz) Measured Power Density Mid (dBm/MHz) High (dBm/MHz) Smart 300N Broadband Router BR485d IEEE 802.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT 8.3 FREQUENCY RANGE LIMIT EN 300 328 Clause 4.3.3.2 For all equipment the frequency shall lie within the band 2.4GHz to 2.4835GHz (fL>2.4GHz and fH<2.4835GHz) TEST EQUIPMENTS Name of Equipment Manufacturer Model Serial Number Calibration Due Spectrum Analyzer R&S FSEK 30 835253/002 SEP. 29, 2012 Temp./Humidity Chamber K.SON THS-M1 242 AUG.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT TEST RESULTS No non-compliance noted Product Name Model Mode Smart 300N Broadband Router BR485d IEEE 802.11b 2011/12/15 Test Date Test By Agun Huang TEMP & Humidity 22℃,51% Frequency Range TEST CONDITIONS Low Frequency MHz High Frequency MHz 230V 2402.63 2480.64 207V 2402.53 2480.79 253V 2402.52 2480.79 207V 2402.72 2480.59 253V 2402.71 2480.60 Measured frequencies (lowest and highest) 2402.52 2480.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Product Name Model Mode Smart 300N Broadband Router BR485d IEEE 802.11n HT20 2011/12/15 Test Date Test By Agun Huang TEMP & Humidity 22℃,51% Frequency Range TEST CONDITIONS Tnom (25 °C) Tmin (0 °C) Tmax (55 °C) Low Frequency(MHz) Chain 0 Chain 1 230V 2402.65 2402.64 2481.39 2481.40 207V 2402.53 2402.54 2481.54 2481.55 253V 2402.52 2402.53 2481.55 2481.53 207V 2402.71 2402.69 2481.29 2481.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT 8.4 TRANSMITTER SPURIOUS EMISSIONS LIMIT ETSI EN 300 328 Subclause 4.3.4.2 limits : The spurious emissions of the transmitter shall not exceed the values in tables 2 and 3 in the indicated bands. Table 2: Transmitter limits for Narrowband Spurious emissions Frequency Range Limit when operating Limit when in standby 30MHz to 1 GHz -36 dBm -57 dBm above 1 GHz to 12.75 GHz -30 dBm -47 dBm -47 dBm -47 dBm 1.8 GHz to 1.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT TEST EQUIPMENTS Open Area Test Site # 6 Name of Equipment Manufacturer Model SUHNER CHA9513 6 NOV. 17, 2012 Sunol JB1 A070506-2 OCT. 03, 2012 LOOP ANTENNA EMCO 6502 8905-2356 JUN. 10, 2012 Pre-Amplifier HP 8447F 2944A03817 NOV. 23, 2012 EMI Receiver R&S ESVS10 833206/012 MAY 10, 2012 RF Cable SUHNER SUCOFLEX104PEA 20520/4PEA NOV. 10, 2012 Horn Antenna Com-Power AH-118 071032 DEC.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT TEST SETUP Substitution Measurement setup below 1GHz Ground plane Antenna mast d: distance in meters 1-4 meter d:3 meter 1.5m Turntable Signal Generator Substituted Dipole antenna Biconical or LP antenna Spectrum analyzer/pre-amp Substitution Measurement setup above 1GHz Ground plane Antenna mast d: distance in meters 1-4 meter d: 3 meter 1.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT The diagram below shows the test setup that is utilized to make the measurements for emission from 30 to 1GHz. 3m EUT & PERIPHERALS PERIPHERALS Antenna Elevation Variable The diagram below shows the test setup that is utilized to make the measurements for emission above 1GHz. 3m EUT & PERIPHERALS PERIPHERALS Antenna Elevation Variable TEST PROCEDURE 1. Please refer to ETSI EN 300 328 (V1.7.1) clause 5.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Below 1GHz Product Name Model Test Mode Smart 300N Broadband Router BR485d TX / CH Low Test Date Test By TEMP& Humidity 2011/12/15 Agun Huang 22℃, 51% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 110.48 53.24 H -60.00 -36.00 -24.00 -4.09 249.99 40.67 H -71.52 -36.00 -35.52 -3.04 312.43 42.19 H -68.30 -36.00 -32.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Product Name Model Test Mode Smart 300N Broadband Router BR485d TX / CH High Test Date Test By TEMP& Humidity 2011/12/15 Agun Huang 22℃, 51% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 110.23 55.43 H -57.81 -36.00 -21.81 -4.09 250.16 41.69 H -70.46 -36.00 -34.46 -3.00 312.02 43.18 H -67.31 -36.00 -31.31 -1.34 468.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Above 1GHz Product Name Model Test Mode Smart 300N Broadband Router BR485d IEEE 802.11b / TX (CH Low) Test Date Test By TEMP& Humidity 2011/12/15 Agun Huang 22℃, 51% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 4824.12 49.51 H -53.24 -30.00 -23.24 6.40 6432.03 48.78 H -51.13 -30.00 -21.13 9.24 4824.16 50.39 V -53.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Product Name Model Test Mode Smart 300N Broadband Router BR485d IEEE 802.11g / TX (CH Low) Test Date Test By TEMP& Humidity 2011/12/15 Agun Huang 22℃, 51% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 4824.16 50.16 H -52.59 -30.00 -22.59 6.40 6432.09 49.25 H -50.66 -30.00 -20.66 9.24 4824.13 50.83 V -53.18 -30.00 -23.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Smart 300N Broadband Router Product Name Test Date BR485d Model Test By IEEE 802.11n HT20 / TX (CH Low) TEMP& Humidity Test Mode 2011/12/15 Agun Huang 22℃, 51% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 4824.24 50.16 H -52.59 -30.00 -22.59 6.40 6432.08 48.97 H -50.94 -30.00 -20.94 9.24 4824.17 52.10 V -51.91 -30.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Smart 300N Broadband Router Product Name Test Date BR485d Model Test By IEEE 802. 11n HT40 / TX (CH Low) TEMP& Humidity Test Mode 2011/12/15 Agun Huang 22℃, 51% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 4844.60 48.67 H -54.01 -30.00 -24.01 6.47 6458.33 46.55 H -53.31 -30.00 -23.31 9.29 4844.60 50.12 V -53.84 -30.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT 8.5 RECEIVER SPURIOUS EMISSIONS LIMIT ETSI EN 300 328 Subclause 4.3.5.2 Limits : The spurious emissions of the receiver shall not exceed the values in table 4 and 5 in the indicated bands. Table 4: Narrowband spurious emission limits for receivers Frequency Range Limit 30MHz to 1 GHz -57 dBm above 1 GHz to 12.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT TEST EQUIPMENTS Open Area Test Site # 6 Name of Equipment Manufacturer Model SUHNER CHA9513 6 NOV. 17, 2012 Sunol JB1 A070506-2 OCT. 03, 2012 LOOP ANTENNA EMCO 6502 8905-2356 JUN. 10, 2012 Pre-Amplifier HP 8447F 2944A03817 NOV. 23, 2012 EMI Receiver R&S ESVS10 833206/012 MAY 10, 2012 RF Cable SUHNER SUCOFLEX104PEA 20520/4PEA NOV. 10, 2012 Horn Antenna Com-Power AH-118 071032 DEC.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT TEST SETUP Substitution Measurement setup below 1GHz Ground plane Antenna mast d: distance in meters 1-4 meter d:3 meter 1.5m Turntable Signal Generator Substituted Dipole antenna Biconical or LP antenna Spectrum analyzer/pre-amp Substitution Measurement setup above 1GHz Ground plane Antenna mast d: distance in meters 1-4 meter d: 3 meter 1.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT The diagram below shows the test setup that is utilized to make the measurements for emission from 30 to 1GHz. 3m EUT & PERIPHERALS PERIPHERALS Antenna Elevation Variable The diagram below shows the test setup that is utilized to make the measurements for emission above 1GHz. 3m EUT & PERIPHERALS PERIPHERALS Antenna Elevation Variable TEST PROCEDURE 1. Please refer to ETSI EN 300 328 (V1.7.1) clause 5.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Below 1GHz Product Name Model Test Mode Smart 300N Broadband Router BR485d RX / CH Low Test Date Test By TEMP& Humidity 2011/12/15 Agun Huang 22℃, 51% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 110.77 49.95 H -63.29 -57.00 -6.29 -4.09 250.00 35.98 H -76.17 -57.00 -19.17 -3.00 312.42 37.68 H -72.81 -57.00 -15.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Product Name Model Test Mode Smart 300N Broadband Router BR485d RX / CH High Test Date Test By TEMP& Humidity 2011/12/15 Agun Huang 22℃, 51% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 110.83 50.08 H -63.16 -57.00 -6.16 -4.09 250.13 36.57 H -75.58 -57.00 -18.58 -3.00 312.43 38.29 H -72.20 -57.00 -15.20 -1.34 468.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Above 1GHz Product Name Model Test Mode Smart 300N Broadband Router BR485d IEEE 802. 11b / RX (CH Low) Test Date Test By TEMP& Humidity 2011/12/15 Agun Huang 22℃, 51% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 4824.10 46.10 H -56.65 -47.00 -9.65 6.40 6432.13 46.31 H -53.60 -47.00 -6.60 9.24 4824.11 47.18 V -56.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Product Name Model Test Mode Smart 300N Broadband Router BR485d IEEE 802. 11g / RX (CH Low) Test Date Test By TEMP& Humidity 2011/12/15 Agun Huang 22℃, 51% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 4824.10 46.33 H -56.42 -47.00 -9.42 6.40 6432.14 46.21 H -53.70 -47.00 -6.70 9.24 4824.12 46.98 V -57.03 -47.00 -10.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Smart 300N Broadband Router Product Name Test Date BR485d Model Test By IEEE 802. 11n HT20 / RX (CH Low) TEMP& Humidity Test Mode 2011/12/15 Agun Huang 22℃, 51% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 4824.12 45.85 H -56.90 -47.00 -9.90 6.40 6432.15 47.08 H -52.83 -47.00 -5.83 9.24 4824.11 48.39 V -55.62 -47.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Smart 300N Broadband Router Product Name Test Date BR485d Model Test By IEEE 802. 11n HT40 / RX (CH Low) TEMP& Humidity Test Mode 2011/12/15 Agun Huang 22℃, 51% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 4844.05 46.26 H -56.42 -47.00 -9.42 6.47 6458.35 45.98 H -53.88 -47.00 -6.88 9.29 4844.58 46.88 V -57.08 -47.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT APPENDIX I PHOTOGRPHS OF TEST SETUP Page 44 / 45 Rev.
Reference No: T110908403-RT Report No: T11112830801-RT Reference No: 90522403-RT Page 45 / 45 Rev.
Reference No T11112830801-RE Report No T11112830801-RE ETSI EN 301 489-17 V2.1.1: 2009 TEST REPORT For Smart 300N Broadband Router Model Number: BR485d Brand : E-TOP Issued to E-TOP Network Technology Inc. No. 82, Gongye 2nd Rd., Tainan City 70955, Taiwan, R.O.C. Issued by Compliance Certification Services Inc. Tainan Lab. No.8,Jiucengling, Xinhua Dist., Tainan City 712, Taiwan (R.O.C.
Reference No T11112830801-RE Report No T11112830801-RE Revision History Rev.
Reference No T11112830801-RE Report No T11112830801-RE TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION..........................................................................4 2. EUT DESCRIPTION..............................................................................................5 3. TEST METHODOLOGY........................................................................................7 3.1 3.2 3.3 3.4 UNIT OF MEASUREMENT ..........................................................................
Reference No T11112830801-RE Report No T11112830801-RE 1. TEST RESULT CERTIFICATION Applicant Address : : Manufacture Address : : Equipment Under Test : E-Top Network Technology Inc. No. 82 ,Gongye 2nd Rd.,Tainan City 70955,Taiwan, R.O.C. E-Top Network Technology Inc. No. 82 ,Gongye 2nd Rd.,Tainan City 70955,Taiwan, R.O.C.
Reference No T11112830801-RE Report No T11112830801-RE 2. EUT DESCRIPTION Product Name Smart 300N Broadband Router Model Number BR485d Brand Name E-TOP Received Date November 28, 2011 Frequency Range Transmit Power Channel Spacing Channel Number Transmit Data Rate Type of Modulation IEEE 802.11b/g ,802.11n HT20 : 2412MHz ~ 2472MHz IEEE 802.11n HT40 : 2422MHz ~ 2462MHz IEEE 802.11a, 802.11n HT20 : 5180MHz ~ 5240MHz IEEE 802.11n HT40 : 5190MHz ~ 5230MHz IEEE 802.11b : 18.71 dBm IEEE 802.
Report No T11112830801-RE Power Source Powered from adapter Model: JKY36-SP1201000 Input: 100-240Vac, 50/60Hz, 0.5A Output: 12Vdc, 1000mA Temperature Range 0 ~ +40°C NOTE: 1. Client consigns one model sample and two adapters to test (Model Number: BR485d). Therefore, the testing Lab. just guarantees the unit, which has been tested. 2. For more details, please refer to the User’s manual of the EUT. 3. To add a series model is for business necessary.
Reference No T11112830801-RE Report No T11112830801-RE 3. TEST METHODOLOGY All tests were performed in accordance with the procedure documented in ETSI EN 301 489-1 V1.6.1 (2005-09) as referenced in ETSI EN 301 489-17 V1.2.1 (2002-04). 3.1 UNIT OF MEASUREMENT Measurements of radiated interference are reported in terms of dB(uV/m) at a specified distance. The indicated readings on the Spectrum analyzers were converted to dB (uV/m) by use of appropriate conversion factors.
Reference No T11112830801-RE Report No T11112830801-RE 3.3 MEASUREMENT EQUIPMENT USED Open Area Test Site # 7 Name of Equipment Manufacturer Model Serial Number Calibration Due TEST RECEIVER Rohde & Schwarz ESCS30 100343 DEC. 06, 2012 TYPE N COAXIAL CABLE SUHNER RG_214_U/2X 7 NOV. 24, 2012 BILOG ANTENNA Sunol sciences JB1 A013105-1 OCT. 05, 2012 Test Software EMI e-3 / AUDIX (5.
Reference No T11112830801-RE Report No T11112830801-RE Power Harmonic & Voltage Fluctuation/Flicker Measurement (EN 61000-3-2&-3-3) Name of Equipment Manufacturer Model Serial Number Calibration Due Harmonics Analyzer TTI HA1600 198202 APR. 11, 2012 H/F Test S/W HA 1600 PC LINK Field Probe Equipment Used for Immunity Measurement ESD Test Site (IEC/EN 61000-4-2) Name of Equipment Manufacturer ESD Simulator NoiseKen Model Serial Number Calibration Due ESS-2002 ESS04Z3762 OCT.
Reference No T11112830801-RE Report No T11112830801-RE Fast Transients/Burst Test Site (IEC/EN 61000-4-4) Name of Equipment Manufacturer Model Serial Number Calibration Due Computer IBM M/T 8183 - ICV N.C.R. VGA Monitor Acer 1555 Keyboard HP KB - 0133 99BG137 91716023058420 0572P5C431 B69360MGAPEO K5 KeyTek EMCpro 0312231 JAN. 13, 2013 EMC Pro IMMUNITY TEST SYSTEM Test S/W N.C.R. N.C.R. CE Ware 3.
Reference No T11112830801-RE Report No T11112830801-RE Voltage Dips/Short Interruption and Voltage Variation Immunity Test Site (IEC/EN 61000-4-11) Name of Equipment Manufacturer Model Serial Number Calibration Due 99BG137 91716023058420 0572P5C431 B69360MGAPEO K5 N.C.R. 0312231 JAN. 13, 2013 Computer IBM M/T 8183 - ICV VGA Monitor Acer 1555 Keyboard HP KB - 0133 KeyTek EMCpro EMC Pro IMMUNITY TEST SYSTEM Test S/W CE Ware 3.00b Page 11 / 50 N.C.R. N.C.R.
Reference No T11112830801-RE Report No T11112830801-RE 3.4 DECISION OF FINAL TEST MODE 1. The following test mode was scanned during the preliminary test: Radiation Modes(Below 1GHz) 1. Normal operation Radiation Modes(Above 1GHz) 1. Normal operation Conduction (Power port) Modes 1. Normal operation Conduction (Telecom port) Modes 1. N/A Immunity Modes 1. 2. Normal operation After the preliminary scan, the following test mode was found to produce the highest emission level.
Reference No T11112830801-RE Report No T11112830801-RE 4. INSTRUMENT AND CALIBRATION 4.1 MEASURING INSTRUMENT CALIBRATION The measuring equipment, which was utilized in performing the tests documented herein, has been calibrated in accordance with the manufacturer’s recommendations for utilizing calibration equipment, which is traceable to recognized national standards. 5. FACILITIES AND ACCREDITATIONS 5.
Reference No T11112830801-RE Report No T11112830801-RE 5.3 LABORATORY ACCREDITATIONS AND LISTINGS The test facilities used to perform radiated and conducted emissions tests are accredited by Taiwan Accreditation Foundation for the specific scope of accreditation under Lab Code: 1109 to perform Electromagnetic Interference tests according to FCC PART 15 AND CISPR 22 requirements. No part of this report may be used to claim or imply product endorsement by TAF or any agency of the Government.
Reference No T11112830801-RE Report No T11112830801-RE 6. SETUP OF EQUIPMENT UNDER TEST 6.1 SETUP CONFIGURATION OF EUT Note Book (1) (B) 3G Modem EUT Note Book (2) (D) (C) (A) HUB (5) Note Book (3) Adapter 6.2 SUPPORT EQUIPMENT No. Product 1 Note Book 2 Manufacturer Model No. Certify No. Signal cable IBM R51 R33026 Power cable, unshd, 1.6m Note Book IBM T43 DoC Power cable, unshd, 1.6m 3 Note Book IBM R50E DoC Power cable, unshd, 1.
Reference No T11112830801-RE Report No T11112830801-RE 6.3 TEST SETUP The equipment under test was configured and operated in a manner to communicate with WLAN continuously. EUT tends to maximize its emission characteristics in a typical application for conducted and radiated emission measurement. The RF module plus ancillary (stand alone unit) was evaluated as per table 2 of clause 7.1 of ETSI Final draft ETSI EN 301 489-1 V1.8.1: 2008.
Reference No T11112830801-RE Report No T11112830801-RE 7. ETSI EN 301 489-1/-17 REQUIREMENTS 7.1 RADIATED EMISSION LIMIT Please refer to ETSI EN 301 489-1 Clause 8.2.3, Table 4 and EN 55022 Clause 6, Table 6, Class B TEST CONFIGURATION Test table & Turntable 1m ~ 4m EUT Power Cable 0.8 m Coaxial Cable 10 m or 3 m Filter Ground Plane To Power EMI Receiver TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 8.2.3 and EN 55022 Clause 6 for the measurement methods.
Reference No T11112830801-RE Report No T11112830801-RE TEST DATA Below 1GHz Model No. BR485d Test Mode Normal operation Environmental Conditions Antenna Pole 27 ℃, 51 % RH Resolution Bandwidth 120 kHz Vertical Antenna Distance 10m Detector Quasi-peak. Taiyu Cyu Tested By Function: (The chart below shows the highest readings taken from the final data.) Note: 1. QP= Quasi-peak Reading. 2. The other emission levels were very low against the limit.
Reference No T11112830801-RE Report No T11112830801-RE Model No. BR485d Test Mode Normal operation Environmental Conditions Antenna Pole 27 ℃, 51 % RH Resolution Bandwidth 120 kHz Horizontal Antenna Distance 10m Detector Quasi-peak. Taiyu Cyu Tested By Function (The chart below shows the highest readings taken from the final data.) Note: 1. QP= Quasi-peak Reading. 2. The other emission levels were very low against the limit.
Reference No T11112830801-RE Report No T11112830801-RE Above 1GHz Model No. BR485d Test Mode Normal Operation Environmental Conditions 23deg.C, 60% RH 6dB Bandwidth 120 kHz Antenna Pole Vertical / Horizontal Antenna Distance 3m Highest frequency work clock frequency generated or used Detector Function Peak & Average Upper frequency See Note Tested by Agun Huang (The chart below shows the highest readings taken from the final data.
Reference No T11112830801-RE Report No T11112830801-RE 7.2 AC MAINS LINE CONDUCTED EMISSION LIMIT Please refer to ETSI EN 301 489-1 Clause 8.4.3, Table 8 and EN 55022 Clause 5, Table 2, Class B. TEST CONFIGURATION Vert. reference plane EMI receiver 40cm EUT 80cm LISN Reference ground plane TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 8.4.3 and EN 55022 Clause 5 for the measurement methods. TEST RESULTS No non-compliance noted.
Reference No T11112830801-RE Report No T11112830801-RE TEST DATA Model No. BR485d Resolution Bandwidth 9 kHz Environmental Conditions 24.8 ℃, 53 % Test Mode Normal operation Tested by Ted Huang Line (The chart below shows the highest readings taken from the final data.) NOTE: 1. Measured Level (dBuV) = LISN Factor (dB) + Cable Loss (dB)+ Meter Reading (dBuV) 2.
Reference No T11112830801-RE Report No T11112830801-RE Model No. BR485d Resolution Bandwidth 9 kHz Environmental Conditions 24.8 ℃, 53 % Test Mode Normal operation Tested by: Ted Huang Neutral (The chart below shows the highest readings taken from the final data.) NOTE: 1. Measured Level (dBuV) = LISN Factor (dB) + Cable Loss (dB)+ Meter Reading (dBuV) 2.
Reference No T11112830801-RE Report No T11112830801-RE 7.3 CONDUCTED EMISSION MEASUREMENT AT TELECOMMUNICATION PORTS LIMITS The telecommunication ports shall meet the class B limits given in EN 55022 [1]. Voltage Limit Current Limit Frequency (dBuV) (dBuA) (MHz) Quasi-peak Average Quasi-peak Average 0.15 - 0.5 84 ~ 74 74 ~ 64 40 ~ 30 30 ~ 20 0.5 - 30.0 74 64 30 20 Note: The limits decrease linearly with the logarithm of the frequency in the range 0,15 MHz to 0,5 MHz.
Reference No T11112830801-RE Report No T11112830801-RE TEST SETUP ● For the actual test configuration, please refer to the related item – Photographs of the Test Configuration.
Reference No T11112830801-RE Report No T11112830801-RE TEST RESULTS Common Mode Conducted Emission (LAN Port) Resolution BR485d Model No. Bandwidth Environmental 24.8 ℃, 63 % Test Mode Conditions Tested by: REMARKS: 9 kHz Mode 1 Ted Huang 1. Level (dBuV) = Read Level (dBuV) + LISN Factor (dB) + Cable Loss (dB) 2.
Reference No T11112830801-RE Report No T11112830801-RE Model No. BR485d Resolution Bandwidth 9 kHz Environmental Conditions 24.8 ℃, 63 % Test Mode Mode 2 Tested by: Ted Huang REMARKS: 1. Level (dBuV) = Read Level (dBuV) + LISN Factor (dB) + Cable Loss (dB) 2.
Reference No T11112830801-RE Report No T11112830801-RE Model No. BR485d Resolution Bandwidth 9 kHz Environmental Conditions 24.8 ℃, 63 % Test Mode Mode 3 Tested by: Ted Huang REMARKS: 1. Level (dBuV) = Read Level (dBuV) + LISN Factor (dB) + Cable Loss (dB) 2.
Reference No T11112830801-RE Report No T11112830801-RE Model No. BR485d Resolution Bandwidth 9 kHz Environmental Conditions 24.8 ℃, 63 % Test Mode Mode 4 Tested by: Ted Huang REMARKS: 1. Level (dBuV) = Read Level (dBuV) + LISN Factor (dB) + Cable Loss (dB) 2.
Reference No T11112830801-RE Report No T11112830801-RE 7.4 AC MAINS HARMONIC CURRENT EMISSION LIMIT Please refer to EN 61000-3-2. TEST CONFIGURATION Harmonic & Flicker Analyzer + Power Source Power Cord Support Units EUT 0.8m TEST PROCEDURE Please refer to EN 61000-3-2 for the measurement methods.
Reference No T11112830801-RE Report No T11112830801-RE 7.5 AC MAINS VOLTAGE FLUCTUATION AND FLICKER LIMIT Please refer to EN 61000-3-3 TEST CONFIGURATION (Same as the configuration of the AC MAINS HARMONIC CURRENT EMISSIONS TEST) TEST PROCEDURE Please refer to EN 61000-3-3 for the measurement methods.
Reference No T11112830801-RE Report No T11112830801-RE Test Result Supply Voltage : 230.0 to 230.1 Vrms 328.7 Vpk Frequency : 49.98 to 50.11 Hz Load Current : 36.1 to 44.1 mArms 224 to 256 mApk Crest Factor: 6.133 Test Method: EN61000-3-3 Highest Level: +0.12% Lowest Level: -0.11% d(max): 0.23% PASS Highest d(t) of 500ms: 0.00% PASS Present d(t) over 3.33%: 0.00 Seconds Longest d(t) over 3.33%: 0.00 Seconds Highest Steady State: +0.05% Lowest Steady State: +0.05% Max d(c) Between Adjacent: 0.
Reference No T11112830801-RE Report No T11112830801-RE 7.6 ELECTROSTATIC DISCHARGE LIMIT Please refer to EN 61000-4-2 TEST CONFIGURATION 10 cm Support units R 0.5 mm Thick Insulator EUT R R 30 cm Wooden Table VCP HCP Wooden Table 0.8 m R R R R =470 kΩ Reference Ground Plan TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.3.2 and EN 61000-4-2 for the measurement methods.
Reference No T11112830801-RE Report No T11112830801-RE TEST RESULTS 26 oC Temperature 1029 mbar Pressure Required Passing Performance Test Points Front Back Left Right Top Bottom Test Points Front Back Left Right Top Bottom ± 2 KV ± 2 KV SIDE OF EUT Front Back Left Right SIDE OF EUT Front Back Left Right Humidity Tested By Air Discharge Test Levels ± 4 KV ± 8 KV ± 12 KV ± 15 KV 46 % RH Vision Chang Transient Phenomena Results Performance Criterion A B C D A B C D A B C D A B C D A B C D A B C D
Reference No T11112830801-RE Report No T11112830801-RE The Photo for Discharge Points of EUT ‘A’ Mark — Air Discharged ; ‘C’ Mark —Contact Discharged Page 35 / 50
Reference No T11112830801-RE Report No T11112830801-RE 7.7 RF ELECTROMAGNETIC FIELD LIMIT Please refer to EN 61000-4-3. TEST CONFIGURATION 3 meter RS Chamber EUT & Support Units 1.5 meter 0.8m Power Amp Signal Generator PC Controller to control S.G. & PA as well as forward power EUT Monitoring by using a camera Control Room TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.2.2 and EN 61000-4-3 for the measurement methods.
Reference No T11112830801-RE Report No T11112830801-RE TEST RESULTS 26 oC Temperature 1029 mbar Pressure Dwell Time Required Passing Performance 46 % RH Vision Chang Humidity Tested By 2.86 sec.
Reference No T11112830801-RE Report No T11112830801-RE 7.8 AC MAINS FAST TRANSIENTS – COMMON MODE LIMIT Please refer to EN 61000-4-4. TEST CONFIGURATION This length should be 0.5m + 0.05m z EFT/Burst Generator Support Units EUT Controller Computer 0.1m GRP To Load AC Line EFT/Burst Generator This length between clamp and EUT should be 0.5m ± 0.05m Injection Clamp EUT Support Units GRP TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.4.2 and EN 61000-4-4 for the measurement methods.
Reference No T11112830801-RE Report No T11112830801-RE TEST RESULTS 26 oC Temperature 1029mbar Pressure Required Passing Performance 46 % RH Vision Chang Transient Phenomena Humidity Tested By POWER Test Point Polarity Test Level (kV) L +/- 1kV A B C D PASS N +/- 1kV A B C D PASS L+ N +/- 1kV A B C D PASS Criteria Result SIGNAL Test Point Polarity Test Level (kV) RJ45 Clamp 0.
Reference No T11112830801-RE Report No T11112830801-RE 7.9 AC MAINS SURGE LIMIT Please refer to EN 61000-4-5. TEST CONFIGURATION To AC Source EUT & Support Units Surge Immunity Test System 0.8m Controller Computer TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.8.2 and EN 61000-4-5 for the measurement methods.
Reference No T11112830801-RE Report No T11112830801-RE 7.10AC MAINS RF – COMMON MODE LIMIT Please refer to EN 61000-4-6. TEST CONFIGURATION TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.5.2, ETSI EN 301 489-17 Clause 7.2.2 and EN 61000-4-6 for the measurement methods. TEST RESULTS 26 oC Temperature 1028 mbar Pressure Required Passing Performance 46% RH Humidity Vision Chang Tested By Continuous Phenomena POWER Frequency Field Band Strength (MHz) (Vrms) Cable Injection Method CDN- 0.
Reference No T11112830801-RE Report No T11112830801-RE 7.11 VOLTAGE DIPS AND INTERRUPTION LIMIT Please refer to EN 61000-4-11. TEST CONFIGURATION To AC Source Dips/Interruption and Variations Simulator EUT & Support Units 0.8m Controller Computer TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.7.2 and EN 61000-4-11 for the measurement methods.
Reference No T11112830801-RE Report No T11112830801-RE 8.
Reference No T11112830801-RE Report No T11112830801-RE TELECOMMUNICATION PORTS Page 44 / 50
Reference No T11112830801-RE Report No T11112830801-RE RADIATED EMISSION TEST Page 45 / 50
Reference No T11112830801-RE Report No T11112830801-RE FLICKER TEST Page 46 / 50
Reference No T11112830801-RE Report No T11112830801-RE ESD TEST RS TEST Page 47 / 50
Reference No T11112830801-RE Report No T11112830801-RE EFT TEST EFT TEST(Clamp) Page 48 / 50
Reference No T11112830801-RE Report No T11112830801-RE SURGE TEST CS TEST Page 49 / 50
Reference No T11112830801-RE Report No T11112830801-RE CS TEST(Clamp) VOLTAGE DIP TEST Page 50 / 50
Report No.:T11112830801-RT-1 ETSI EN 301 893 V1.5.1:2008 TEST REPORT For Smart 300N Broadband Router Model : BR485d Trade Name : E-TOP Issued for E-Top Network Technology Inc. No. 82 ,Gongye 2nd Rd.,Tainan City 70955,Taiwan, R.O.C. Issued by Compliance Certification Services Inc. Tainan Lab. No.8,Jiucengling, Xinhua Dist., Tainan City 712, Taiwan (R.O.C.) TEL: 886-6-580-2201 FAX: 886-6-580-2202 http://www.ccsrf.com E-Mail : service@ccsrf.
Report No.:T11112830801-RT-1 Revision History Rev. Issue Date Revisions Effect Page Revised By 00 February 08, 2012 Initial Issue ALL Sunny Chang Page 2 of 48 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No.:T11112830801-RT-1 TABLE OF CONTENTS TITLE PAGE NO. 1. TEST REPORT CERTIFICATION ............................................................................................. 4 2. EUT DESCRIPTION .................................................................................................................. 5 3. DESCRIPTION OF TEST MODES ............................................................................................ 7 4. TEST METHODOLOGY ..........................................
Report No.:T11112830801-RT-1 1. TEST REPORT CERTIFICATION Applicant Address : : Manufacture Address : : Equipment Under Test : Model Number : Brand Name : Date of Test : E-Top Network Technology Inc. No. 82 ,Gongye 2nd Rd.,Tainan City 70955,Taiwan, R.O.C. E-Top Network Technology Inc. No. 82 ,Gongye 2nd Rd.,Tainan City 70955,Taiwan, R.O.C. Smart 300N Broadband Router BR485d E-TOP November 29, 2011 ~ December 29, 2011 APPLICABLE STANDARD Standard Test Result ETSI EN 301 893 V1.5.
Report No.:T11112830801-RT-1 2. EUT DESCRIPTION Product Name Smart 300N Broadband Router Model Number BR485d Identify Number T11112830801 Received Date November 28, 2011 Frequency Range Transmit Power (mean EIRP) IEEE 802.11a, 802.11n HT20 : 5180MHz ~ 5240MHz, IEEE 802.11n HT40 : 5190MHz ~ 5230MHz, IEEE 802.11a : 11.64 dBm IEEE 802.11n HT20 : 12.28 dBm IEEE 802.11n HT40 : 11.03 dBm Channel Spacing Channel Number IEEE 802.11a, 802.11n HT20 : 20MHz IEEE 802.11n HT40 : 20MHz IEEE 802.11a, 802.
: Report No. T11112830801-RT-1 Multiple listing: Page 6 of 48 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No.:T11112830801-RT-1 3. DESCRIPTION OF TEST MODES The EUT is an 802.11n MIMO transceiver in Smart 300N Broadband Router form factor. It has two transmitter chains and two receive chains (2×2 configurations). The 2 × 2 configuration is implemented with two outside chains (Chain 0, 1). 11a mode, only Chain 0 transmitter. HT20, HT40 mode only Chain 0 transmitter and two Chain 0, 1 transmitter. IEEE 802.11a mode, IEEE 802.11n HT20 mode The EUT had been tested under operating condition.
Report No.:T11112830801-RT-1 4. TEST METHODOLOGY The tests documented in this report were performed in accordance with ETSI EN 301 893 V1.5.1:2008 – Broadband Radio Access Networks (BRAN); 5 GHz high performance RLAN; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive 5. FACILITIES AND ACCREDITATION 5.1 FACILITIES All measurement facilities used to collect the measurement data are located at No.8,Jiucengling, Xinhua Dist., Tainan City 712, Taiwan (R.O.C.
Report No.:T11112830801-RT-1 5.2 ACCREDITATIONS Our laboratories are accredited and approved by the following accreditation body according to ISO/IEC 17025. Taiwan TAF The measuring facility of laboratories has been authorized or registered by the following approval agencies. Canada Industry Canada Germany TUV NORD Taiwan BSMI USA FCC Copies of granted accreditation certificates are available for downloading from our web site, http:///www.ccsrf.com 5.
Report No.:T11112830801-RT-1 6. SETUP OF EQUIPMENT UNDER TEST SUPPORT EQUIPMENT No. Product 1 Note Book Manufacturer Model No. Certify No. IBM T43 DoC Signal cable Power cable, unshd, 1.6m No. Signal cable description A DC Power Unshielded, 1.2m, 1pcs B LAN Cable Unshielded, 1.0m, 1pcs SETUP DIAGRAM FOR TESTS EUT & peripherals setup diagram is shown in appendix setup photos.
Report No.:T11112830801-RT-1 EUT OPERATING CONDITION RF Setup 1. Set up all computers like the setup diagram. 2. Reset equipment and burn in the test program “MP_Test”. 3.
Report No.:T11112830801-RT-1 7. ETSI EN 301 893 REQUIREMENTS 7.1 CENTRE FREQUENCIES DEFINITION ETSI EN 301 893 clause 4.2.1 The centre frequency is the centre of the channel declared by the manufacturer as part of the declared channel plan(s). LIMITS ETSI EN 301 893 clause 4.2.2 The actual centre frequency for any given channel declared by the manufacturer shall be maintained within the range fc ± 20 ppm.
Report No.:T11112830801-RT-1 TEST RESULTS Product Name Model Test Mode Smart 300N Broadband Router Test By BR485d Test Date IEEE 802.11a / 20℃, 230Vac Temp. & Humidity Normal Condition Results John Chen 2011/11/29 21.8°C, 55% Frequency (MHz) Measured Frequency (MHz) Delta Frequency (kHz) 20 ppm Limit (± kHz) Margin (kHz) 5180 5180.08821 88.21 103.60 -15.39 5240 5240.08818 88.18 104.80 -16.62 Product Name Model Test Mode Smart 300N Broadband Router Test By BR485d Test Date IEEE 802.
Report No.:T11112830801-RT-1 Product Name Model Test Mode Smart 300N Broadband Router Test By BR485d Test Date IEEE 802.11a / 40℃, 207Vac Temp. & Humidity Extreme Condition Results John Chen 2011/11/29 21.8°C, 55% Frequency (MHz) Measured Frequency (MHz) Delta Frequency (kHz) 20 ppm Limit (± kHz) Margin (kHz) 5180 5180.08817 88.17 103.60 -15.43 5240 5240.08815 88.15 104.80 -16.65 Product Name Model Test Mode Smart 300N Broadband Router Test By BR485d Test Date IEEE 802.
Report No.:T11112830801-RT-1 Product Name Model Test Mode Smart 300N Broadband Router BR485d IEEE 802.11n HT20 / 0℃, 207Vac Extreme Condition Results Test By Test Date John Chen 2011/11/29 Temp. & Humidity 21.8°C, 55% Frequency (MHz) Measured Frequency (MHz) Delta Frequency (kHz) 20 ppm Limit (± kHz) Margin (kHz) 5180 5180.08821 88.21 103.60 -15.39 5240 5240.08828 88.28 104.80 -16.52 Product Name Model Test Mode Smart 300N Broadband Router BR485d IEEE 802.
Report No.:T11112830801-RT-1 Product Name Model Test Mode Smart 300N Broadband Router John Chen Test By BR485d 2011/11/29 Test Date IEEE 802.11n HT20 / 40℃, 253Vac Temp. & Humidity 21.8°C, 55% Extreme Condition Results Frequency (MHz) Measured Frequency (MHz) Delta Frequency (kHz) 20 ppm Limit (± kHz) Margin (kHz) 5180 5180.08823 88.23 103.60 -15.37 5240 5240.08826 88.26 104.80 -16.
Report No.:T11112830801-RT-1 Product Name Model Test Mode Smart 300N Broadband Router BR485d IEEE 802.11n HT40 / 0℃, 253Vac Extreme Condition Results Test By Test Date John Chen 2011/11/29 Temp. & Humidity 21.8°C, 55% Frequency (MHz) Measured Frequency (MHz) Delta Frequency (kHz) 20 ppm Limit (± kHz) Margin (kHz) 5190 5190.09695 96.95 103.80 -6.85 5230 5230.09698 96.98 104.60 -7.
Report No.:T11112830801-RT-1 7.2 RF OUTPUT POWER, TRANSMIT POWER CONTROL (TPC) AND POWER DENSITY DEFINITION ETSI EN 301 893 clause 4.4.1 RF Output Power : The RF output power is the mean equivalent isotropically radiated power (EIRP) during a transmission burst. Transmit Power Control (TPC) : Transmit Power Control (TPC) is a mechanism to be used by the RLAN device to ensure a mitigation factor of at least 3 dB on the aggregate power from a large number of devices.
Report No.:T11112830801-RT-1 RF output power at the lowest power level of the TPC range For devices using TPC, the RF output power during a transmission burst when configured to operate at the lowest stated power level of the TPC range shall not exceed the levels given in table 2.
Report No.:T11112830801-RT-1 TEST SETUP Temperature and Voltage Measurement (under normal and extreme test conditions) Test Configuration for Power Density TEST PROCEDURE 1. Please refer to ETSI EN 301 893 (V1.5.1) clause 5.3.4.1 for the test conditions. 2. Please refer to ETSI EN 301 893 (V1.5.1) clause 5.3.4.2 for the measurement method. Page 20 of 48 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No.:T11112830801-RT-1 TEST RESULTS Power Density Product Name Model Test Mode Smart 300N Broadband Router Test By BR485d Test Date IEEE 802.11a Temp. & Humidity Duty Cycle measurement X: 10 * log (1/x) = Antenna Gain Chain 0: (Ton/Ton + Toff) = Vnor 1.00 0.00 dB 4 dBi TRANSMITTER POWER (dBm) Mean Frequency Reading Limit EIRP (MHz) (dBm) (dBm) (dBm) TEST CONDITIONS Tnom (20 °C) John Chen 2011/11/29 21.8°C, 55% Margin (dB) 5180 -12.79 3.51 10 -6.49 5240 -13.55 2.75 10 -7.
Report No.:T11112830801-RT-1 Product Name Model Test Mode Smart 300N Broadband Router BR485d IEEE 802.11n HT40 Duty Cycle measurement X: 10 * log (1/x) = Antenna Gain Chain 0: Test By Test Date John Chen 2011/11/29 Temp. & Humidity 21.8°C, 55% (Ton/Ton + Toff) = 1.00 0.00 dB 4 dBi TRANSMITTER POWER (dBm) Reading (dBm) Frequency Mean EIRP Limit Temperature Voltage (MHz) (dBm) (dBm) Chain 0 Chain 1 (°C) (V) TEST CONDITIONS 20°C Margin (dB) 5190 -19.03 -18.33 0.64438805 10 -9.
Report No.:T11112830801-RT-1 OUTPUT POWER Product Name Model Test Mode Smart 300N Broadband Router BR485d IEEE 802.11a Duty Cycle measurement X: 10 * log (1/x) = Antenna Gain Chain 0: TEST CONDITIONS Test By Test Date John Chen 2011/11/29 Temp. & Humidity 21.8°C, 55% (Ton/Ton + Toff) = 1.00 0.00 dB 4 dBi Mean EIRP Density Margin Limit (dB) (dBm/MHz) Frequency (MHz) Reading (dBm/MHz) Mean EIRP Density (dBm/MHz) 5180 10.31 15.11 23.00 -7.89 5240 9.72 14.52 23.00 -8.48 5180 13.51 18.
Report No.:T11112830801-RT-1 Product Name Model Test Mode Smart 300N Broadband Router BR485d IEEE 802.11n HT20 Duty Cycle measurement X: 10 * log (1/x) = Antenna Gain Chain 0: TEST CONDITIONS Test By Test Date John Chen 2011/11/29 Temp. & Humidity 21.8°C, 55% (Ton/Ton + Toff) = Frequency (MHz) 1.00 0.00 dB 4 dBi Mean EIRP Mean EIRP Margin Density Density (dB) Limit Chain 0 Chain 1 (dBm/MHz) (dBm/MHz) Reading (dBm/MHz) 5180 6.95 6.44 14.51 23.00 -8.49 5240 6.28 6.12 14.01 23.00 -8.
Report No.:T11112830801-RT-1 Product Name Model Test Mode Smart 300N Broadband Router BR485d IEEE 802.11n HT40 Duty Cycle measurement X: 10 * log (1/x) = Antenna Gain Chain 0: TEST CONDITIONS Test By Test Date John Chen 2011/11/29 Temp. & Humidity 21.8°C, 55% (Ton/Ton + Toff) = Frequency (MHz) 1.00 0.00 dB 4 dBi Mean EIRP Mean EIRP Margin Density Density (dB) Limit Chain 0 Chain 1 (dBm/MHz) (dBm/MHz) Reading (dBm/MHz) 5180 6.94 6.13 14.36 23.00 -8.64 5230 6.14 5.87 13.82 23.00 -9.
Report No.:T11112830801-RT-1 7.3 TRANSMITTER UNWANTED EMISSIONS OUTSIDE THE 5 GHZ RLAN BANDS DEFINITION ETSI EN 301 893 clause 4.5.1.1 These are radio frequency emissions outside the 5 GHz RLAN bands. LIMITS ETSI EN 301 893 clause 4.5.1.2 The level of unwanted emission shall not exceed the limits given in table 3.
Report No.:T11112830801-RT-1 TEST EQUIPMENT Open Area Test Site # 6 Name of Equipment Manufacturer Model Serial Number Calibration Due SUHNER CHA9513 6 NOV. 17, 2012 Sunol JB1 A070506-2 OCT. 03, 2012 LOOP ANTENNA EMCO 6502 8905-2356 JUN. 10, 2012 Pre-Amplifier HP 8447F 2944A03817 NOV. 23, 2012 EMI Receiver R&S ESVS10 833206/012 MAY 10, 2012 RF Cable SUHNER SUCOFLEX104PEA 20520/4PEA NOV. 10, 2012 Horn Antenna Com-Power AH-118 071032 DEC.
Report No.:T11112830801-RT-1 TEST SETUP Substitution Measurement setup below 1GHz Ground plane Antenna mast d: distance in meters 1-4 meter d:3 meter 1.5m Turntable Signal Generator Substituted Dipole antenna Biconical or LP antenna Spectrum analyzer/pre-amp Substitution Measurement setup above 1GHz Ground plane Antenna mast d: distance in meters 1-4 meter d: 3 meter 1.
Report No.:T11112830801-RT-1 The diagram below shows the test setup that is utilized to make the measurements for emission above 1GHz. TEST PROCEDURE 1. Please refer to ETSI EN 301 893 (V1.5.1) clause 5.3.5.1 for the test conditions. 2. Please refer to ETSI EN 301 893 (V1.5.1) clause 5.3.5.2 for the measurement method. Page 29 of 48 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No.:T11112830801-RT-1 TEST RESULTS Below 1GHz After we verified, the IEEE 802.11n HT20 mode of channel Low is worse case. Product Name Smart 300N Broadband Router Test By John Chen Model BR485d IEEE 802.11n HT20 TX / CH Low Test Date 2011/12/29 Test Mode Temp. & Humidity 21.9°C, 58% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 110.24 56.69 H -56.55 -54.00 -2.55 -4.09 250.00 38.84 H -73.
Report No.:T11112830801-RT-1 Above 1GHz Product Name Smart 300N Broadband Router Test By John Chen Model BR485d IEEE 802.11a TX / CH Low Test Date 2011/11/29 Test Mode Temp. & Humidity 20.9°C, 56% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 6187.69 51.27 H -49.37 -30.00 -19.37 8.51 10360.03 43.28 H -49.09 -30.00 -19.09 16.78 6187.72 53.79 V -47.78 -30.00 -17.78 7.58 10360.02 44.
Report No.:T11112830801-RT-1 Product Name Smart 300N Broadband Router Test By John Chen Model BR485d IEEE 802.11n HT20 TX / CH Low Test Date 2011/11/29 Test Mode Temp. & Humidity 20.9°C, 56% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 6187.69 50.22 H -50.42 -30.00 -20.42 8.51 10360.03 43.92 H -48.45 -30.00 -18.45 16.78 6187.66 53.41 V -48.16 -30.00 -18.16 7.58 10360.03 45.11 V -48.
Report No.:T11112830801-RT-1 Product Name Smart 300N Broadband Router Test By John Chen Model BR485d IEEE 802.11n HT40 TX / CH Low Test Date 2011/11/29 Test Mode Temp. & Humidity 20.9°C, 56% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 6187.68 50.07 H -50.57 -30.00 -20.57 8.51 10360.04 42.94 H -49.43 -30.00 -19.43 16.78 6187.68 53.69 V -47.88 -30.00 -17.88 7.58 10360.04 44.33 V -48.
Report No.:T11112830801-RT-1 7.4 TRANSMITTER UNWANTED EMISSIONS WITHIN THE 5 GHZ RLAN BANDS DEFINITION ETSI EN 301 893 clause 4.5.2.1 These are radio frequency emissions within the 5 GHz RLAN bands. LIMITS ETSI EN 301 893 clause 4.5.2.2 Figure 1: Transmit spectral power mask Note: dBc is the spectral density relative to the maximum spectral power density of the transmitted signal.
Report No.:T11112830801-RT-1 TEST EQUIPMENT Name of Equipment Manufacturer Model Serial Number Calibration Due Spectrum Analyzer R&S FSEK 30 835253/002 SEP. 29, 2012 Remark: Each piece of equipment is scheduled for calibration once a year. TEST SETUP TEST PROCEDURE 1. Please refer to ETSI EN 301 893 (V1.5.1) clause 5.3.6.1 for the test conditions. 2. Please refer to ETSI EN 301 893 (V1.5.1) clause 5.3.6.2 for the measurement method.
Report No.:T11112830801-RT-1 TEST RESULTS CH Low ( IEEE 802.11a Mode ) CH High ( IEEE 802.11a Mode ) Page 36 of 48 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No.:T11112830801-RT-1 CH Low ( IEEE 802.11n HT20 Mode ) Chain 0 CH High ( IEEE 802.11n HT20 Mode ) Chain 0 Page 37 of 48 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No.:T11112830801-RT-1 CH Low ( IEEE 802.11n HT20 Mode ) Chain 1 CH High ( IEEE 802.11n HT20 Mode ) Chain 1 Page 38 of 48 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No.:T11112830801-RT-1 CH Low ( IEEE 802.11n HT40 Mode ) Chain 0 CH High ( IEEE 802.11n HT40 Mode ) Chain 0 Page 39 of 48 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No.:T11112830801-RT-1 CH Low ( IEEE 802.11n HT40 Mode ) Chain 1 CH High ( IEEE 802.11n HT40 Mode ) Chain 1 Page 40 of 48 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No.:T11112830801-RT-1 7.5 RECEIVER SPURIOUS EMISSIONS DEFINITION ETSI EN 301 893 clause 4.6.1 Receiver spurious emissions are emissions at any frequency when the equipment is in receive mode. LIMITS ETSI EN 301 893 clause 4.6.2 The spurious emissions of the receiver shall not exceed the limits given in table 4.
Report No.:T11112830801-RT-1 TEST EQUIPMENT Open Area Test Site # 6 Name of Equipment Manufacturer Model Serial Number Calibration Due SUHNER CHA9513 6 NOV. 17, 2012 Sunol JB1 A070506-2 OCT. 03, 2012 LOOP ANTENNA EMCO 6502 8905-2356 JUN. 10, 2012 Pre-Amplifier HP 8447F 2944A03817 NOV. 23, 2012 EMI Receiver R&S ESVS10 833206/012 MAY 10, 2012 RF Cable SUHNER SUCOFLEX104PEA 20520/4PEA NOV. 10, 2012 Horn Antenna Com-Power AH-118 071032 DEC.
Report No.:T11112830801-RT-1 TEST SETUP Substitution Measurement setup below 1GHz Ground plane Antenna mast d: distance in meters 1-4 meter d:3 meter 1.5m Turntable Signal Generator Substituted Dipole antenna Biconical or LP antenna Spectrum analyzer/pre-amp Substitution Measurement setup above 1GHz Ground plane Antenna mast d: distance in meters 1-4 meter d: 3 meter 1.
Report No.:T11112830801-RT-1 The diagram below shows the test setup that is utilized to make the measurements for emission below 1GHz. The diagram below shows the test setup that is utilized to make the measurements for emission above 1GHz. TEST PROCEDURE 1. Please refer to ETSI EN 301 893 (V1.5.1) clause 5.3.7.1 for the test conditions. 2. Please refer to ETSI EN 301 893 (V1.5.1) clause 5.3.7.2 for the measurement method.
Report No.:T11112830801-RT-1 TEST RESULTS Below 1GHz After we verified, the IEEE 802.11n HT20 mode of channel Low is worse case. Product Name Smart 300N Broadband Router Test By John Chen Model BR485d IEEE 802.11n HT20 RX / CH Low Test Date 2011/12/29 Test Mode Temp. & Humidity 21.9°C, 58% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 111.32 50.23 H -62.95 -57.00 -5.95 -4.03 250.00 36.02 H -76.
Report No.:T11112830801-RT-1 Above 1GHz Product Name Smart 300N Broadband Router Test By John Chen Model BR485d Test Date 2011/11/29 Test Mode RX / CH Low Temp. & Humidity 20.9°C, 56% Frequency (MHz) Reading (dBμV) Antenna Polarization (V/H) Emission level (dBm) Limit (dBm) Margin (dB) Correction Factor (dB) 1250.01 48.92 H -63.91 -47.00 -16.91 -3.68 1597.80 46.39 H -64.38 -47.00 -17.38 -1.62 1250.00 46.92 V -66.26 -47.00 -19.26 -4.03 10360.01 42.46 V -50.80 -47.
Report No.:T11112830801-RT-1 APPENDIX SETUP PHOTOS Page 47 of 48 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No.:T11112830801-RT-1 Page 48 of 48 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Reference: No: T1109084031-RH Report No: T11112830801-RH Reference No: 90522403-RT EN 62311: 2008 TEST REPORT For Smart 300N Broadband Router Model: BR485d Trade Name: E-TOP Issued to E-Top Network Technology Inc. No. 82 ,Gongye 2nd Rd.,Tainan City 70955,Taiwan, R.O.C. Issued by Compliance Certification Services Inc. Tainan Lab. No.8,Jiucengling, Xinhua Dist., Tainan City 712, Taiwan (R.O.C.) TEL: 886-6-580-2201 FAX: 886-6-580-2202 Issued Date: February 08, 2012 Page 1 / 11 Rev.
Reference: No: T1109084031-RH Report No: T11112830801-RH Reference No: 90522403-RT Revision History Rev. Issue Date Revisions Effect Page Revised By 00 February 08, 2012 Initial Issue ALL Sunny Chang Page 2 / 11 Rev.
Reference: No: T1109084031-RH Report No: T11112830801-RH Reference No: 90522403-RT TABLE OF CONTENTS 1. TEST RESULT CERTIE-TOPATION ................................................. 4 2. EUT DESCRIPTION ........................................................................... 5 3. FACILITIES AND ACCREDITATIONS .............................................. 7 3.1 FACILITIES ...................................................................................... 7 3.2 EQUIPMENT ..........................
Reference: No: T1109084031-RH Report No: T11112830801-RH Reference No: 90522403-RT 1. TEST RESULT CERTIE-TOPATION Applicant: E-Top Network Technology Inc. No. 82 ,Gongye 2nd Rd.,Tainan City 70955,Taiwan, R.O.C. Manufacture E-Top Network Technology Inc. No. 82 ,Gongye 2nd Rd.,Tainan City 70955,Taiwan, R.O.C.
Reference: No: T1109084031-RH Report No: T11112830801-RH Reference No: 90522403-RT 2. EUT DESCRIPTION Product Smart 300N Broadband Router Trade Name E-TOP Model Number BR485d Received Date November 28, 2011 Module Trade Name Realtek Module Model Number RTL8192DE IEEE 802.11b/g ,802.11n HT20 : 2412MHz ~ 2472MHz IEEE 802.11n HT40 : 2422MHz ~ 2462MHz IEEE 802.11a, 802.11n HT20 : 5180MHz ~ 5240MHz IEEE 802.11n HT40 : 5190MHz ~ 5230MH z IEEE 802.11b : 18.71 dBm IEEE 802.11g : 18.34 dBm IEEE 802.
Report No: T11112830801-RH Note: 1. Client consigns one model sample to test (Model Number: BR485d).Therefore, the testing Lab. just guarantees the unit, which has been tested. 2. To add a series model is for business necessary. The different of the each model is shown as bellows: Multiple listing: I/O PORT I/O PORT TYPES Q’TY TESTED WITH N/A --- --- Page 6 / 11 Rev.
Reference: No: T1109084031-RH Report No: T11112830801-RH Reference No: 90522403-RT 3. FACILITIES AND ACCREDITATIONS 3.1 FACILITIES All measurement facilities used to collect the measurement data are located at No. 199, Chunghsen Road, Hsintien City, Taipei Hsien, Taiwan, R.O.C. Tel: 886-2-2217-0894 / Fax: 886-2-2217-1029 No. 11, Wugong 6th Rd., Wugu Industrial Park, Taipei Hsien 248, Taiwan Tel: 886-2-2299-9720 / Fax: 886-2-2298-4045 No.81-1, Lane 210, Bade 2nd Rd.
Reference: No: T1109084031-RH Report No: T11112830801-RH Reference No: 90522403-RT 3.3 TABLE OF ACCREDITATIONS AND LISTINGS Our laboratories are accredited and approved by the following accreditation body according to ISO/IEC 17025. Taiwan TAF The measuring facility of laboratories has been authorized or registered by the following approval agencies.
Reference: No: T1109084031-RH Report No: T11112830801-RH Reference No: 90522403-RT 4. EN 62311 REQUIREMENT 4.1 HUMAN EXPOSURE TO THE ELECTROMAGNETIC FIELDS LIMIT Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the following limits. TEST RESULTS No non-compliance noted Since average output power at worst case is IEEE 802.11b : 18.74 dBm 0.0748 W IEEE 802.11g : 18.34 dBm 0.
Reference: No: T1109084031-RH Report No: T11112830801-RH Reference No: 90522403-RT 4.2 HUMAN EXPOSURE ASSESSMENT EUT parameter (data from the separate report) IEEE 802.11b : 18.74 dBm 0.0748 Max average output power in Watt IEEE 802.11g : 18.34 dBm 0.0682 (TP) IEEE 802.11n HT20 : 18.23 dBm 0.0665 IEEE 802.11n HT40 : 18.40 dBm 0.0692 IEEE 802.11b/g/n HT20/n HT40: 3 dBi Antenna gain (2.4G) (Numeric gain: 2) Safety distance 0.
Reference: No: T1109084031-RH Report No: T11112830801-RH Reference No: 90522403-RT EUT parameter (data from the separate report) IEEE 802.11a : 19.10 dBm 0.0813 W Max average output power in Watt IEEE 802.11n HT20 : 18.13 dBm 0.065 W (TP) IEEE 802.11n HT40 : 17.65 dBm 0.0582 W IEEE 802.11a/n HT20/n HT40: 4 dBi Antenna gain (5G) (Numeric gain: 2.51) Safety distance 0.
: Compliance Certification Services Inc. Report No T11112830801-LV TEST REPORT IEC / EN 60950-1 Information Technology Equipment – Safety – Part 1:General requirements Report reference No……………….: T11112830801-LV Date of Issue.……………………. .: Mar., 01, 2012 Total number of pages.………..….: 72 Testing laboratory …………………: Compliance Certification Services Inc. Location……………………………..: No.8,Jiucengling, Xinhua Dist., Tainan City 712, Taiwan (R.O.C.) Test Place…………………………..: 6 F,No.605,Zhongshan Rd.,Xinhua Dist.
Compliance Certification Services Inc. Report No:T11112830801-LV Test item particulars: Equipment mobility ...........…......……......................... Movable Connection to the mains…..…………………………… Not directly connected to the mains Operating Condition..…………………………………… Continuous Overvoltage category (OCV)…………………………… Other : no connection to the mains. Access location ………………………………….……… Operator accessible Mains supply tolerance (%)………………………..…… -Tested for IT power systems…………….……………..
Compliance Certification Services Inc. : Report No T11112830801-LV Comments: Sample Number: Test sample(s) without serial number(s). General product information : 1. The equipment is a movable for general use in information technology equipment. 2. All models are identical except product name, model designation and trade-mark for marketing purpose. 3. The external power adapters are approved products which were evaluated according to EN 60950-1, for detail information see appended table 1.5.1. 4.
Compliance Certification Services Inc. Report No:T11112830801-LV Report revise record: No. Issue Date Report Number Rev.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict 1 General P 1.5 Components P 1.5.1 General P Comply with IEC 60950 or relevant component Components that were found to affect standard safety aspects comply with the requirements of this standard or with the safety aspects of the relevant IEC component standards. (see appended table 1.5.1) P 1.5.
: Compliance Certification Services Inc. Report No T11112830801-LV IEC/EN 60950-1 Clause 1.7 Requirement - Test Result - Remark P P Marking and instructions 1.7.1 Power rating and identification markings 1.7.1.1 Power rating markings Verdict See below P Multiple mains supply connections Not connect to the mains supply. N Rated voltage(s) or voltage range(s) (V) Optional, (not connect to the mains supply) P Symbol for nature of supply for d.c. only. Optional, IEC 60417, Symbol No.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause 1.7.8.3 Requirement - Test Result - Remark Symbols according to IEC 60417 Verdict N 1.7.8.4 Markings using figures No figures used. N 1.7.9 Isolation of multiple power sources Class III equipment. N 1.7.10 Thermostats and other regulating devices No thermostats or other regulating devices. N 1.7.11 Durability The label was subjected to the permanence of marking test.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark b) Internal battery connected to the d.c. mains supply Verdict N 2.1.1.9 Audio amplifiers No such parts. N 2.1.2 Protection in service access areas No maintenance work in operation mode necessary. N 2.1.3 Protection in restricted access locations The unit is not intended to be used in restricted locations. N 2.2 SELV circuits 2.2.1 See below. P 2.2.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark b) Impedance limited output Verdict (see appended table 2.5) P c) Regulating network limited output under (see appended table 2.5) normal operating and single fault condition P d) Overcurrent protective device limited output Max. output voltage (V), max. output current (A), max. apparent power (VA) (see appended table 2.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause 2.7 2.7.1 Requirement - Test Result - Remark Verdict Overcurrent and earth fault protection in primary circuits N Basic requirements N Class III equipment. Instruction when protection relies on building installation N 2.7.2 Faults not simulated in 5.3.7 N 2.7.3 Short-circuit backup protection N 2.7.4 Number and location of protective devices N 2.7.5 Protection by several devices N 2.7.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause 2.10.1.6 Requirement - Test Result - Remark Verdict Special separation requirements N 2.10.1.7 Insulation in circuits generating Starting pulses N 2.10.2 Determination of working voltage N 2.10.2.1 General N 2.10.2.2 RMS working voltage N 2.10.2.3 Peak working voltage N 2.10.3 Clearances N 2.10.3.1 General N 2.10.3.2 Main Transient voltage N a)AC mains supply N b)Earthed d.c.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict Electric strength test N 2.10.5.11 Insulation in wound components N 2.10.5.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict 3.1.1 Current rating and overcurrent protection All internal wires are UL recognized wiring which is PVC insulated, rated VW-1, min. 80°C. Internal wiring is PVC insulated, the wiring gauge is suitable for current intended to be carried. P 3.1.2 Protection against mechanical damage Class III equipment. N 3.1.3 Securing of internal wiring Class III equipment. N 3.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict 3.3.1 Wiring terminals N 3.3.2 Connection of non-detachable power supply cords N 3.3.3 Screw terminals N 3.3.4 Conductor sizes to be connected N Rated current (A), type and nominal thread diameter (mm) N 3.3.5 Wiring terminal sizes N Rated current (A), type and nominal thread diameter (mm) N 3.3.6 Wiring terminals design N 3.3.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause 4.2.3 Requirement - Test Result - Remark Steady force test, 30N Verdict 4.2.4 Steady force test, 250N Class III equipment. N N 4.2.5 Impact test Class III equipment. N Fall test N Swing test N 4.2.6 Drop test Movable equipment. N 4.2.7 Stress relief Class III equipment. N 4.2.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict -Unintentional charging of a non-rechargeable battery N -Reverse charging of a rechargeable battery N Excessive discharging rate for any battery N 4.3.9 Oil and grease N 4.3.10 Dust, powders, liquids and gases Equipment in intended use not considered to be exposed to these. N 4.3.11 Containers for liquids or gases No container for liquid or gases. N 4.3.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict Use of symbol or warning N 4.5 Thermal requirements P 4.5.1 General See below P 4.5.2 Temperature rise (see appended table 4.5) P Normal load condition per Annex L Maximum normal load according to the operation manual. P 4.5.3 Temperature limits for materials (see appended table 4.5) P 4.5.4 Touch temperature limits (see appended table 4.5) P 4.5.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict 4.7.3.4 Materials for components and other parts inside Internal components except small parts fire enclosures. are V-2 or better. P 4.7.3.5 Materials for air filter assemblies No air filter assemblies N 4.7.3.6 Materials used in high-components No high voltage components. N 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS P 5.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict 5.2 Electric strength Class III equipment. N 5.2.1 General N 5.2.2 Test procedure N 5.3 Abnormal operating and fault conditions P 5.3.1 Protection against overload and abnormal operation Ventilation opening blocked. (see appended table 5.3) P 5.3.2 Motors No motors N 5.3.3 Transformers No transformers. N 5.3.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict Current limiting method ─ 7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS N 7.1 General N 7.2 Protection of cable distribution system service personnel, and users of other equipment connected to the system, from hazards voltage in the equipment. N 7.3 Protection of equipment users from overvoltages on the cable distribution system N 7.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict A.2.5 Test procedure N A.2.6 Compliance criteria N Sample 1 burning time(s) ……………….….. : ─ Sample 2 burning time(s) ……………….….. : ─ Sample 3 burning time(s) ……………….….. : ─ Alternative test acc. To IEC 60695-11-5, cl. 5 and 9 N Sample 1 burning time(s) ……………….….. : ─ Sample 2 burning time(s) ……………….….. : ─ Sample 3 burning time(s) ………….……….. : ─ A.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict B.7.1 General N B.7.2 Test procedure N B.7.3 Alternative test procedure N B.7.4 Electric strength test; test voltage (V) N B.8 Test for motors with capacitors N B.9 Test for three-phase motors N B.10 Test for series motors N Operating voltage (V) …………………….. : ─ ANNEX C, TRANSFORMERS(see 1.5.4 and 5.3.3) N Position …………………………………….
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict G.2.1 AC mains supply ─ G.2.2 Earthed d.c. mains supplies ─ G.2.3 Unearthed d.c. amins supplies ─ G.2.4 Battery operation ─ G.3 G.4 Determination of telecommunication network transient voltage (V) ………..……….. : Determination of required withstand voltage(V) ……………………….…………….. : N N G.4.1 Mains transients and internal repetitive peaks ─ G.4.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict L.2 Adding machines and cash registers N L.3 Erasers N L.4 Pencil sharpeners N L.5 Duplicators and copy machines N L.6 Motor-operated files N L.7 Other business equipment M ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) N M.1 Introduction N M.2 Method A N M.3 Method B N M.3.1 Ringing signal N M.3.1.1 Frequency(Hz) ……………….………………..
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause R R.1 Requirement - Test Result - Remark ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL PROGRAMMES Minimum separation distances for unpopulated coated printed boards(see 2.10.6.2) Verdict N N R.2 Reduced clearances (see 2.10.3) N S ANNEX S, PROCEDURE FOR IMPULSE TESTING(see 6.2.2.3) N S.1 Test equipment N S.2 Test procedure N S.
Compliance Certification Services Inc. Report No:T11112830801-LV IEC/EN 60950-1 Clause Requirement - Test Result - Remark Verdict Y.1 Test apparatus ................................................. N Y.2 Mounting of test samples ................................. N Y.3 Carbon-arc light-exposure apparatus .............. N Y.4 Xenon-arc light exposure apparatus ................ N Z ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2) P AA ANNEX AA, MANDREL TEST (see 2.10.5.
Compliance Certification Services Inc. Report No:T11112830801-LV 1.5.1 TABLE: List of critical components Object/part No. Plastic Enclosure Manufacturer/ trademark Various Type/model P Technical data Standard (Edition / year) Mark(s) of conformity1) Various HB or better, thickness min. 1.6 mm. UL 94 UL Power Adaptor Shenzhen Jiakeyuan Industry Co., Ltd. JKY36SP1201000 I/P : AC 100240V, 50/60Hz, 0.5A max, O/P : 12Vdc, 1.
Compliance Certification Services Inc. Report No:T11112830801-LV 2.2.3 TABLE : SELV measurement (under fault conditions) Location N Voltage measured (V) Comments -Note : 2.4.2 TABLE : limited current circuit measurement Location N Voltage Current Freq. Limit (V) (mA) (kHz) (mA) Comments -Note : 2.5 TABLE : limited power source measurement Limits P Measured Verdict According to Table 2B (Normal conditions) : USB1, USB port, Uoc=4.975V Current (in A) ≤8.0 2.
Compliance Certification Services Inc. Report No:T11112830801-LV 4.3.8 TABLE: Batteries N The tests of 4.3.8 are applicable only when appropriate battery data is not available Is it possible to install the battery in a reverse polarity position? Non-rechargeable batteries Discharging Meas. current Manuf. Specs. Unintentional charging Rechargeable batteries Charging Meas. current Discharging Manuf. Specs. Meas. current Manuf. Specs. Reversed charging Meas. current Manuf. Specs.
Compliance Certification Services Inc. Report No:T11112830801-LV Tamb 23.3 22.3 -- For Power Adaptor : Shenzhen Jiakeyuan / JKY36-SP1201000 Operating condition : C -- 01. THR3 (Thermister) 52.0 -- 02. C2 60.6 105 03. PCB near U1 67.2 130 04. T1 coil 61.5 110 05. T1 core 61.8 110 06. CY1 (Y Cap.) 58.7 125 07. IC2 (photo coupler) 56.9 100 08. PCB near D7 58.5 130 09. C5 60.6 105 10. Plastic enclosure inside near T1 49.8 -- 11. Plastic enclosure outside near T1 47.
Compliance Certification Services Inc. Report No:T11112830801-LV 4.6.1 & 4.6.2 Ventilation opening Location N Dimensions (mm) Remark Horizontal mode : Front -- No opening. Rear -- No opening except I/O ports. Top 3.0 by 1.35 Provided with numerous openings. Bottom 2.0 by 16.0 Provided with numerous openings, also provided two key shaped each measures 17.6 by 4.7 by 4.0 mm. Left side -- No opening. Right side -- No opening. Vertical mode : Front 3.0 by 1.
Compliance Certification Services Inc. Report No:T11112830801-LV 5.2 TABLE: Electric strength tests, impulse tests and voltage surge tests Test voltage applied between: Voltage shape Test voltage (AC, DC, (V) impulse, surge) N Breakdown Yes/No -Supplementary information: 5.3 TABLE: Fault condition tests P ⎯ 25, if not specified. Ambient temperature (°C) ................................... : Power source for EUT: Manufacturer, model/type, (see appended table 1.5.1) output rating ...................
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark Verdict EN 60950-1:2006/A11:2009/A1:2010/A12:2011 – CENELEC COMMON MODIFICATIONS IEC60950-1, GROUP DIFFERENCES (CENELEC common modifications EN) Contents General General (A1:2010) P Add the following annexes : Annex ZA (normative) Normative references to international publications with their corresponding Europearn publications.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test (A12:2011) conditions, particularly providing protection against exposure to excessive sound pressures from headphones or earphones.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark Verdict − is designed to allow the user to listen to recorded or broadcast sound or video; and − primarily uses headphones or earphones that can be worn in or on or around the ears; and − allows the user to walk around while in use.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test in EN 50332-1; and - a personal music player provided with an analogue electrical output socket for a listening device, where the electrical output is ≤ 27 mV measured as described in EN 50332-2, while playing the fixed “programme simulation noise” as described in EN 503321.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark Verdict produced by the programme simulation noise, the warning does not need to be given as long as the average sound pressure of the song is below the basic limit of 85 dBA. In this case T becomes the duration of the song. NOTE 4 Classical music typically has an average sound pressure (long term LAeq,T) which is much lower than the average programme simulation noise.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark Verdict example built-in volume level control). NOTE The values of 94 dBA – 75 mV correspond with 85dBA – 27 mV and 100 dBA – 150 mV. Zx.4.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark Verdict equipment or as parts of the building installation, subject to the following, a), b) and c): a) except as detailed in b) and c), protective devices necessary to comply with the requirements of 5.3 shall be included as parts of the equipment; b) for components in series with the mains input to the equipment such as the supply cord, appliance coupler, r.f.i.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark 4.3.13.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test 1.7.2.1 Add as new SNC: In Norway and Sweden, the screen of the cable distribution system is normally not earthed at the entrance of the building and there is normally no equipotential bonding system within the building. Therefore the protective earthing of the building installation need to be isolated from the screen of a cable distribution system.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause 2.2.4 2.3.2 2.3.4 2.6.3.3 2.7.1 2.10.5.13 3.2.1.1 3.2.1.1 Requirement − Test For CLASS II EQUIPMENT the socket outlet shall be in accordance with Standard Sheet DKA 1-4a. In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex. In Finland, Norway and Sweden there are additional requirements for the insulation. See 6.1.2.1 and 6.1.2.2 of this annex. In Norway, for requirements see 1.7.2.1, 6.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause 3.2.1.1 3.2.1.1 3.2.1.1 3.2.4 3.2.5.1 Requirement − Test Result – Remark protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or DK 2-5a.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause 3.3.4 4.3.6 4.3.6 5.1.7.1 6.1.2.1 (A1:2010) Requirement − Test Result – Remark equipment with a rated current over 10 A and up to and including 13 A. In the United Kingdom, the range of conductor sizes of flexible cords to be accepted by terminals for equipment with a RATED CURRENT of over 10 A up to and including 13 A is: • 1,25 mm2 to 1,5 mm2 nominal crosssectional area.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause 6.1.2.2 Requirement − Test Result – Remark consist of either two layers of thin sheet material, each of which shall pass the electric strength test below, or one layer having a distance through insulation of at least 0,4 mm, which shall pass the electric strength test below. If this insulation forms part of a semiconductor component (e.g.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test 7.2 EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B and equipment intended to be used in a RESTRICTED ACCESS LOCATION where equipment bonding has been applied, e.g. in a telecommunication centre, and which has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark FINLAND NATIONAL DIFFERENCES (EN 60950-1:2006/A11:2009/A1:2010/A12:2011) 1.5.7.1 1.5.9.4 1.7.2.1 In Finland resistors bridging BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in 1.5.7.1. In addition when a single resistor is used, the resistor must withstand the resistor test in 1.5.7.2.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark 6.1.2.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause 6.1.2.2 7.2 Requirement − Test Result – Remark sequence of tests as described in EN 60384-14:2005. The exclusions are applicable for PERMANENTLY CONNECTED EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B and equipment intended to be used in a RESTRICTED ACCESS LOCATION where equipment bonding has been applied, e.g.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark GERMANY NATIONAL DIFFERENCES (VDE 0805-1:2011-01) Annex ZC, 1.7.2.1 According to GPSG, section 2, clause 4: If certain rules on the use, supplementation or maintenance of an item of technical work equipment or ready-to-use commodity must be observed in order to guarantee safety and health, instructions for use in German must be supplied when it is brought into circulation.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark KOREAN NATIONAL DIFFERENCES (K60950-1) 1.5.101 8 Addition: Plugs for the connection of the apparatus to the supply mains shall comply with the Korean requirement (KSC 8305). Addition: EMC The apparatus shall comply with the relevant CISPR standards. Page 51 of 72 Verdict P No supply cord provided. N Compliance shall be evaluated during national approval.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark CANADIAN NATIONAL DIFFERENCES (CAN/CSA C22.2 No. 60950-1-07, Second Edition) 1.1.1 1.4.14 1.5.5 1.7.1 1.7.7 2.5 2.7.1 All equipment is to be designed to allow installation in accordance with the National Electrical Code (NEC), ANSI/NFPA 70, the Canadian Electrical Code (CEC), Part I, CAN/CSA C22.1, and when applicable, the National Electrical Safety Code, IEEE C2.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause 3.2 3.2.1 3.2.1.2 3.2.3 3.2.5 3.2.9 3.3 3.3.3 3.3.4 3.4.2 3.4.8 3.4.11 Requirement − Test Result – Remark distribution units) if the supply branch circuit protection is not suitable. Power distribution transformers distributing power at 100 volts or more, and rated 10 kVA or more, require special transformer overcurrent protection. Wiring methods (terminals, leads, etc.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause 4.3.12 4.3.13.5 4.7 4.7.3.1 Annex H Requirement − Test Result – Remark 750 VA for five minutes are required to have a battery disconnect means that may be connected to the computer room remote poweroff circuit. The maximum quantity of flammable liquid stored in equipment is required to comply with NFPA 30.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause 1.6.1.2 2.3.1 2.3.2.1 2.6.3.3 2.6.3.4 4.2.8.1 4.3.2 5.1.8.3 5.3.7 6.4 M.2 Requirement − Test thermostats, (multilayer) transformer winding wire, transient voltage surge suppressors, tubing, wire connectors, and wire and cables.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Annex NAD are permitted if the equipment is subjected to special installation and performance restrictions. Equipment connected to a telecommunication and cable distribution networks and supplied with an earphone intended to be held against, or in the ear is required to comply with special acoustic pressure requirements. Page 56 of 72 Result – Remark Verdict No TNV circuits.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark US NATIONAL DIFFERENCES (UL 60950-1, Second Edition) 1.1.1 1.4.14 1.5.5 1.7.1 2.5 2.7.1 3.2 3.2.1 3.2.1.2 Verdict P All equipment is to be designed to allow installation in accordance with the National Electrical Code ANSI/NFPA 70, and when applicable, the National Electrical Safety Code, IEEE C2.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark 3.2.3 Permanent connection of equipment to the mains supply by a power supply cord is not permitted, except for certain equipment, such as ATMs. Power supply cords are required to be no longer than 4.5 m in length and minimum length shall be 1.5 m. Flexible power supply cords are required to be compatible with Article 400 of the NEC.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark Annex H Equipment that produces ionizing radiation must comply with Federal Regulations, 21 CFR 1020 No CRTs. Verdict N OTHER NATIONAL DIFFERENCES 1.5.1 1.6.1.2 2.3.1 2.3.2.1 2.6.3.
Compliance Certification Services Inc. Report No:T11112830801-LV National Differences Clause Requirement − Test Result – Remark Verdict conditions specified. 4.2.8.1 4.2.11 4.3.2 5.1.8.3 5.3.7 6.4 M.2 Annex NAD Annex NAF Enclosures around CRTs with a face diameter of 160 mm or more are required to reduce the risk of injury due to the implosion of the CRT.
Compliance Certification Services Inc. Report No:T11112830801-LV Attachment –A.
Compliance Certification Services Inc.
Compliance Certification Services Inc.
Compliance Certification Services Inc.
Compliance Certification Services Inc.
Compliance Certification Services Inc.
Compliance Certification Services Inc. Report No:T11112830801-LV Attachment - B.
Compliance Certification Services Inc.
Compliance Certification Services Inc. Report No:T11112830801-LV Attachment – C.
Compliance Certification Services Inc. Report No:T11112830801-LV Attachment - D.
Compliance Certification Services Inc. Report No:T11112830801-LV Attachment - E.
Compliance Certification Services Inc. Report No:T11112830801-LV Id Code Kind of Instrument Manufacturer Model / type Serial No. V K5E118 Mobile Recorder YOKOGAWA MV230-2-21-1D 12A525267 V K5E123 DC Electronic Load Prodigit 3310C 30402C216 V K5E126 Oven Ten Billion TPO-1 TBN-920510 V K5E127 Test Pin TESTING ----------- K5E127 V K5E168 V K5E179 V K5E183 Digital Timer Electronic Scale Steel Rule -G.