Operation Manual

Kapitel 4Einstellungen — Menü [NETZWERK]
178 - DEUTSCH
Inhalt der gesendeten E-Mail
Beispiel der gesendeten E-Mail, wenn E-Mail eingestellt ist
Die folgende E-Mail wird versendet, wenn die E-Mail-Einstellungen eingerichtet wurden.
=== Panasonic project or report(CONF IGURE) ===
Project or T ype : RZ12K
Serial No : 123456789012
----- E-mail setup data -----
TEMPERATURE WARNING SETUP
MINIMUM TIME at [ 60] minutes interval
INTAKE AI R TEMPERAT URE Over [ 46 degC / 114 degF ]
ERROR [ OFF ]
INTAKE AIR TEMPERATURE [ OFF ]
PERIO DIC REPORT
Sunday [ O N ] Monday [ O N ] Tuesday [ O N ] Wednesday [ O N ]
Thursday [ O N ] Friday [ ON ] Sat urday [ ON ]
00:00 [ ON ] 01: 00 [ O N ] 02:00 [ O N ] 03:00 [ O N ]
04:00 [ ON ] 05: 00 [ O N ] 06:00 [ O N ] 07:00 [ O N ]
08:00 [ ON ] 09: 00 [ O N ] 10:00 [ O N ] 11:00 [ O N ]
12:00 [ ON ] 13: 00 [ O N ] 14:00 [ O N ] 15:00 [ O N ]
16:00 [ ON ] 17: 00 [ O N ] 18:00 [ O N ] 19:00 [ O N ]
20:00 [ ON ] 21: 00 [ O N ] 22:00 [ O N ] 23:00 [ O N ]
----- check system -----
MAIN CPU BUS [ OK ]
FAN [ OK ]
INTAKE AIR TEMPERATURE [ OK ]
OPTICS MODULE TEMPERATURE [ OK ]
EXHAUST AIR TEMPERATURE [ OK ]
LD1 TEMPERATURE [ OK ]
LD2 TEMPERATURE [ OK ]
LD1 STATUS [ OK ]
LD2 STATUS [ OK ]
SHUTTER(MUTE-SHUT T ER) [ O K ]
INTAKE AIR TEMP.SENSOR [ OK ]
FILTER UNIT [ OK ]
AIR FILTER [ OK ]
AC VOLTAGE [ OK ]
(Error code 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00)
Intake air temperature : 30 degC / 86 degF
Optics module temperature : 39 degC / 102 degF
Exhaust air temperature : 32 degC / 89 degF
Around light1 temperat ure : 34 degC / 93 degF
Around light2 temperat ure : 34 degC / 93 degF
PROJECT OR RUNTIME 77 H
POWER O N 1906 times
LD1-1 O N 1906 times
LD1-1 RUNT IME 76 H
LD1-2 O N 1906 times
LD1-2 RUNT IME 76 H
LD1-3 O N 1906 times
LD1-3 RUNT IME 76 H
LD1-4 O N 1906 times
LD1-4 RUNT IME 76 H
LD1-5 O N 1906 times
LD1-5 RUNT IME 76 H
LD1-6 O N 1906 times
LD1-6 RUNT IME 76 H
LD2-1 O N 1900 times
LD2-1 RUNT IME 75 H
LD2-2 O N 1900 times
LD2-2 RUNT IME 75 H
LD2-3 O N 1900 times
LD2-3 RUNT IME 75 H
LD2-4 O N 1900 times
LD2-4 RUNT IME 75 H
LD2-5 O N 1900 times
LD2-5 RUNT IME 75 H
LD2-6 O N 1900 times
LD2-6 RUNT IME 75 H
-------- Current status ---------
MAIN VERSION 0.24
SUB VERSION 0.04. 01
LD STAT US
LD1-1=ON LD1-2=ON LD1-3=O N LD1-4=OFF LD1-5=OF F LD1-6=ON
LD2-1=ON LD2-2=ON LD2-3=O N LD2-4=OFF LD2-5=OF F LD2-6=OF F
INPUT SDI1
SIGNAL NAME ---
SIGNAL F REQUENCY ---kHz / ---Hz
REMOTE2 STATUS DISABLE
----- Wired Network configuration -----
DHCP Client O FF
IP address 192.168.0.8
MAC address 12:34:56:78:90:12
Mon Jan 01 12: 34: 56 20XX
----- Memo -----