Operation Manual
Table Of Contents
- Read this first!
- Chapter 1 Preparation
- Chapter 2 Getting Started
- Chapter 3 Basic Operations
- Switching on/off the projector
- Projecting
- Operating with the remote control
- Switching the input
- Using the shutter function
- Using the on-screen display function
- Using the automatic setup function
- Switching the image aspect ratio
- Using the function button
- Displaying internal test pattern
- Using the status function
- Using the AC voltage monitor function
- Setting ID number of the remote control
- Chapter 4 Settings
- Menu navigation
- [PICTURE] menu
- [POSITION] menu
- [ADVANCED MENU] menu
- [DISPLAY LANGUAGE] menu
- [3D SETTINGS] menu
- [DISPLAY OPTION] menu
- [COLOR MATCHING]
- [LARGE SCREEN CORRECTION]
- [SCREEN SETTING]
- [AUTO SIGNAL]
- [AUTO SETUP]
- [BACKUP INPUT SETTING]
- [SIMUL INPUT SETTING]
- [RGB IN]
- [DVI-D IN]
- [HDMI IN]
- [DIGITAL LINK IN]
- [SDI IN]
- [ON-SCREEN DISPLAY]
- [IMAGE ROTATION]
- [BACK COLOR]
- [STARTUP LOGO]
- [UNIFORMITY]
- [SHUTTER SETTING]
- [FREEZE]
- [WAVEFORM MONITOR]
- [CUT OFF]
- [PROJECTOR SETUP] menu
- [PROJECTOR ID]
- [PROJECTION METHOD]
- [OPERATION SETTING]
- [LIGHT OUTPUT]
- [BRIGHTNESS CONTROL]
- [STANDBY MODE]
- [NO SIGNAL SHUT-OFF]
- [NO SIGNAL LIGHTS-OUT]
- [INITIAL STARTUP]
- [STARTUP INPUT SELECT]
- [DATE AND TIME]
- [SCHEDULE]
- [RS-232C]
- [REMOTE2 MODE]
- [FUNCTION BUTTON]
- [LENS CALIBRATION]
- [LENS MEMORY]
- [STATUS]
- [AC VOLTAGE MONITOR]
- [SAVE ALL USER DATA]
- [LOAD ALL USER DATA]
- [INITIALIZE]
- [SERVICE PASSWORD]
- [P IN P] menu
- [TEST PATTERN] menu
- [SIGNAL LIST] menu
- [SECURITY] menu
- [NETWORK] menu
- Chapter 5 Maintenance
- Chapter 6 Appendix

Chapter 4 Settings — [NETWORK] menu
176 - ENGLISH
Example of the E-mail sent for an error
The following E-mail is sent when an error has occurred.
=== Panasonic project or report (ERRO R) ===
Project or T ype : RZ 12K
Serial No : 123456789012
----- check system -----
MAI N CPU BUS [ FAILED ]
FAN [ OK ]
INTAKE AIR TEMPERATURE [ OK ]
OPTICS MODULE TEMPERATURE [ OK ]
EXHAUST AIR TEMPERATURE [ OK ]
LD1 TEMPERATURE [ OK ]
LD2 TEMPERATURE [ OK ]
LD1 STATUS [ OK ]
LD2 STATUS [ OK ]
SHUT T ER(MUTE-SHUT T ER) [ O K ]
INTAKE AIR TEMP.SENSOR [ OK ]
OPTICS MODULE TEMP.SENSOR [ OK ]
EXHAUST AIR TEMP.SENSOR [ OK ]
LD1 TEMP.SENSOR [ OK ]
LD2 TEMP.SENSOR [ OK ]
PO WER CI RCUI T T EMPERAT URE [ O K ]
FPGA TEMPERATURE [ OK ]
BATTERY [ OK ]
LENS MO UNTER [ OK ]
BRIGHTNESS SENSOR [ OK ]
PHOSPHOR WHEEL1 [ OK ]
PHOSPHOR WHEEL2 [ OK ]
FILTER UNIT [ OK ]
AIR F ILTER [ OK ]
AC VOLTAGE [ OK ]
(Error code 80 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00)
Intake air t emperature : 30 degC / 86 degF
O pt ics module temperat ure : 39 degC / 102 degF
Exhaust air t emperature : 32 degC / 89 degF
Around light1 temperat ure : 34 degC / 93 degF
Around light2 temperat ure : 34 degC / 93 degF
PRO JECT O R RUNT I ME 77 H
PO WER O N 1906 times
LD1-1 O N 1906 times
LD1-1 RUNT I ME 76 H
LD1-2 O N 1906 times
LD1-2 RUNT I ME 76 H
LD1-3 O N 1906 times
LD1-3 RUNT I ME 76 H
LD1-4 O N 1906 times
LD1-4 O N 1906 times
LD1-4 RUNT I ME 76 H
LD1-5 O N 1906 times
LD1-5 RUNT I ME 76 H
LD1-6 O N 1906 times
LD1-6 RUNT I ME 76 H
LD2-1 O N 1900 times
LD2-1 RUNT I ME 75 H
LD2-2 O N 1900 times
LD2-2 RUNT I ME 75 H
LD2-3 O N 1900 times
LD2-3 RUNT I ME 75 H
LD2-4 O N 1900 times
LD2-4 RUNT I ME 75 H
LD2-5 O N 1900 times
LD2-5 RUNT I ME 75 H
LD2-6 O N 1900 times
LD2-6 RUNT I ME 75 H
-------- Current status ---------
MAIN VERSION 0.24
SUB VERSION 0. 04. 01
LD STAT US
LD1-1=ON LD1-2=O N LD1-3=O N LD1-4=OF F LD1-5=OF F LD1-6=O N
LD2-1=ON LD2-2=O N LD2-3=O N LD2-4=OF F LD2-5=OF F LD2-6=O F F
INPUT SDI1
SIGNAL NAME ---
SIG NAL F REQUENCY ---kHz / ---Hz
REMOTE2 STATUS DISABLE
----- Wired Network configuration -----
DHCP Client OFF
IP address 192.168.0.8
MAC address 12:34:56:78:90:12
Mon Jan 01 12: 34: 56 20XX