INSTRUCTION MANUAL LCD Monitor Please read this Instruction book before using your LCD monitor. We wish you many hours of pleasure from your new LCD monitor.
GB TABLE OF CONTENTS TABLE OF CONTENTS. . . . . . . . . . . . . . . . . . . . . . . . . 2 Time menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Setup menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 SAFETY PRECAUTIONS. . . . . . . . . . . . . . . . . . . . . . . . 3 PC Adj. menu. . . . . . . . . . . . . . . . .
SAFETY PRECAUTIONS GB GB CAUTION: Please read and retain for your safety. This unit has been designed and manufactured to assure your personal safety, but improper use can result in potential electric shock or fire hazards. In order not to defeat the safeguards incorporated in this monitor observe the following basic rules for its installation, use and servicing. Installation and Use Do not allow anything to rest on the power cord.
SERVICING GB GB Servicing Your monitor is fully transistorised and does not contain any user serviceable components. You must not remove the rear cover of the monitor by yourself. The apparatus is working with high voltages and could damage objects or even endanger people. Leave all required repair and service jobs to an authorised service technician. He will exclusively use such spare parts that are complying with the same safety standards as applicable to the original parts.
GB SERVICING GB AC Power Cord Requirement The AC Power Cord supplied with this LCD monitor meets the requirement for use in the country in which you purchase it. AC Power Cord for the United States and Canada: AC Power Cord used in the United States and Canada is listed by the Underwriters Laboratories (UL) and certified by the Canadian Standard Association (CSA). GROUND AC Power Cord has a grounding-type AC line plug. This is a safety feature to make sure that the plug will fit into the power outlet.
INSTALLATION GB GB Step: 1 Mains Connection n Connect the display unit to VGA, BNC and Scart connector as required. LD-Net * This figure is 42 inch model. 1. Connect the in-line power connector to the Mains Inlet as shown above. 2. Connect the power cord of the LCD monitor to a suitable wall outlet. ✐ As this product does not have a mains On/Off switch, please ensure your mains plug is easily accessible. 4. AV3 Composite (CVBS) signal input.
GB INSTALLATION GB Remote control Standby Input To switch input source from AV1, RGB, AV2, AV3, PC, DVI or Network mode. To switch the monitor on and off. Also see page 8. Recall Wide To select the screen mode Full, Full All, Zoom 16:9, Title in 16:9, Zoom 14:9, Title in 14:9, Normal or Natural wide. Refer to page 12. Menu To enter and exit the main menu, and sub menu. To display input selection information and the Time set.
GB INSTALLATION GB Controls and Menus Menu Operation Many of your monitors functions are controlled through the menu function, using the remote control.
MENU OPERATION GB Picture menu n Advanced settings Use the 5 or 6 button to select Advanced settings and press the 1 or 2 button to enter the sub menu as follows. GB n Current Weekday Use to set current weekday using the 1 or 2 button. n Current Time Use to set the current time using the Numeric buttons. ✐ Other items in Time Menu should not be selected until Current Time has been set.
GB MENU OPERATION GB V_Sets is used to divide the vertical picture into more than one part, and the most is also 5 parts (5 monitors). Using the 1 or 2 button to set. H Location is used to select one part of the horizonal picture to display on the current LCD Monitor using the 1 or 2 button. V Location is used to select one part of the vertical picture to display on the current LCD Monitor using the 1 or 2 button. Language is used to select the preferred language.
INSTALLATION MODE GB Installation Mode Installation Mode On program Tuner Menu Max Volume Winter mode RC inhibition Child Lock Address Baud rate Panel protection AV Auto shut off Network Standby On Timer Function LED light setting DCR Network initial Temperature Error IP Address Subnet Gateway DNS Select Adjust G2.
OPERATION GB GB Selection of picture size Select screen size from FULL, FULL ALL, ZOOM 16:9, TITLE IN 16:9, ZOOM 14:9, TITLE IN 14:9, NORMAL or NATURAL WIDE by pressing the WIDE button repeatedly on the Remote Control. ✐W hen in AV2 (RGBHV) or PC mode FULL or NORMAL can be selected. Note: Full - Set display area 100% ✐O nly in DVI or AV2 (YPbPr) displaying high resolution content FULL and FULL ALL are selectable.
OPERATION GB GB PIP/POP Operation Using this function, you can enjoy a DVI or Network program and an image (AV1, AV2, AV3 or PC input) at the same time. Press the ON/OFF button on the Remote Control repeatly to select PIP1, PIP2, POP or OFF mode. During the PIP/POP mode, press the Main/Sub Picture Swap button will switch the location for main and sub picture. ✐O nly the sound on the main picture is heard from the monitor speaker. The sound on the sub-picture cannot be heard.
OPERATION (IN TEXT MODE) GB Teletext Operation Teletext is only available via external sources. Teletext mode can be operated by the following buttons on the Remote Control. ✐S ome buttons have dual functions. GB Text Cancel Press the TEXT CANCEL button in TEXT or MIX mode, the TV picture appears on the screen. Press this button once again or press TXT/TV button, CANCEL mode will be cancelled. In CANCEL mode, “CAN” is always displayed on the upper left of the screen.
SPECIFICATIONS/HELPFUL HINTS GB Specification GB Helpful hints Common specification n NO PICTURE NO SOUND Power source: 100 ~ 240V 50Hz/60Hz ¡Check if monitor is plugged in. Colour system: PAL/NTSC/NTSC4.43/SECAM ¡Check monitor is not in standby mode. AV terminal AV1: Scart CENELEC Standard Input: C omposite video, RGB (5V RGB with 5V sync to pin 14) and audio-L/R Output: composite video from AV3 and audio L/R n POOR PICTURE ¡Adjust BRIGHTNESS/CONTRAST levels (too low).
DIMENSIONS GB GB n CE42SR2 Unit: mm 989.0 925.4 (WALL MOUNT SCREW) 10 x M6, 1.0 PITCH x 12MM 418.4 1027.0 953.0 930.25 VIEWING AREA(H) 165.9 126.0 418.4 400.0 200.0 100.0 50.8 41.8 523.0 VIEWING AREA(V) 400.0 200.0 Handles x 2 292.0 300.6 546.0 620.0 17.6 178.5 402.9 417.9 Control buttons 43.7 ø4.2 (RC RECEIVER) Cables exit terminal cover ø4.2 (LED INDICATOR) n CE52SR2 Unit: mm 217 193.8 176.7 1304 1120.6 997 1303 1216 1152 376.5 358.4 117.6 Handles x 4 227.
GB PC/DVI-D/COMPONENT SIGNAL SUPPORT TIMING LIST n PC signal support timing Resolution Horizontal Frequency (kHz) Vertical Frequency (Hz) GB n DVI-D signal support timing Remark Resolution Horizontal Frequency (kHz) Vertical Frequency (Hz) Remark 720 x 400 31.47 70.09 DOS (VGA) 640 x 480 31.43 59.88 VGA VESA 60Hz 640 x 480 31.43 59.88 VGA VESA 60Hz 640 x 480 37.86 72.81 VGA VESA 72Hz 640 x 480 37.50 75.00 VGA VESA 75Hz 640 x 480 37.5 75 VGA VESA 75Hz 640 x 480 37.86 72.
RS232C COMMAND TABLES GB n Functional Execution Command Table Command Item GB n Image control Read Command Table Status read command Item C00 POWER ON CR BRIGHT Status of Brightness. C01 POWER OFF CR CONT Status of Contrast. C24 Wide “Natural” direct CR COLOR Status of Color. C25 Wide “Zoom 16:9” direct CR TINT Status of Tint. C26 Wide “Title in 16:9” direct CR SHARP Sharpness.
RS232C COMMAND TABLES GB GB n Time Read Command Table Status read command n UK5 Read Command Table (Basic Command) Item CR PANELH Status of accumulated lifetime of panel. (The same as CR_LAMPH Command) CR MONH Status of accumulated lifetime of monitor. (The same as CR_PROJH Command) n Sound control Read Command Table Status read command Item CR VOLUME Status of volume value. CR MUTE Status of MUTE. Command Item Note CR0 Power On, Standby, power error, CR1 Input Mode AV1, AV2, . . .
N7RRM/N7RMM/N7RSL/N7RTL/N7WVT/N7WWS/N7WYS SANYO Electric Co., Ltd.