4.1 Changing F ilters
After opening the unit’s door, grasp both edges of fil-
ter and pull with equal force to slide out the filter.
4.2 Cleaning
Once a year or as needed, clean the interior of the
unit (Wall and motor plates) using mild non-abrasive
soap and water. It is recommended to use products
that are environmentally friendly.
M
L
Door
Interlock
Brown
N
Blue
Black
2.5uf
7.5uf
G
Speed
Selection
UV Power
Supply cord for
optional UV module
When should I service my unit?
service and accessories
Detailed maintenance information is located
on the front decal on motor plate.
PRE-FILTER
Replace filters every 3 to 6 months or
as needed.
HEPA FILTER
Replace filter every 2 to 5 years or as need-
ed. Check regular ly to maintain maximum
performance from your
HVAC system.
For replacement filters, contact your local
HVAC contractor.
UV LAMP
Replace lamp every 3 years. Lamps are
available through your local HVAC contractor.
INSIDE THE UNIT
Once a year or as needed, clean the interior
of the unit (Wall and Motor Plate) with a
mild and non-abrasive soap. It is recom-
mended to use products that are environ-
mentally friendly.
Note
IMPORTANT: ALWAYS UNPLUG UNIT
BEFORE SERVICING
4.4 Electrical W iring Diagram
4.3 Troubleshooting
Maintenance GUIDE
4. Gener al Maintenance Information
Troubleshooting Suggestions
Unit does not operate. Is power cord fully inserted in the
unit’s connector?
Is outlet pow ered?
Is door interlock s witch operating?
Unit operates only on one speed. P ossible loose wire inside electrical box,
contact your local contractor .
Unit vibrates.
Check for excessive dust buildup or missing
balancing w eight on the impeller w heel.