Specifications

10
8.0 FAULT FINDING
YOUR SANTON SPEEDIBOIL SHOULD GIVE TROUBLE FREE OPERATION,
HOWEVER SHOULD A FAULT OCCUR THE TABLE BELOW SHOULD ALLOW
MOST FAULTS TO BE IDENTIFIED. FAULT FINDING SHOULD ONLY BE CAR-
RIED OUT BY A COMPETENT PERSON.
SYMPTOM POSSIBLE CAUSE
ACTION
No indicator light
1. If no water or heat - no power to
unit
2. If no water available - no power to
indicator diodes
1. Check power supply is correctly
connected and switched on and that
primary cutout has not operated
2. Check connections to indicators at
4 way plug
Unit does not fill on commisioning
1. If “ON” indicator not illuminated
no power to unit
2. Solenoid valve fault
3. Low water pressure
1. Check power supply is correctly
connected and switched on and that
primary cutout has not operated
2. Check operation of solenoid valve,
replace if necessary
3. Check supply is turned on
Unit does not heat on commisioning
1. If “ON” indicator not illuminated
no power to unit
2. Solenoid valve fault
3. Low water pressure
4. Element fault
1. Check power supply is correctly
connected and switched on and that
primary cutout has not operated
2. Check operation of solenoid valve,
replace if necessary
3. Check supply
4. Check element continuity. If faulty
replace
NOTE: Maintenance must be carried out by competent persons.
Competent - i.e. Trained, experienced, qualied.
Disconnect the electrical supply before removing the cover.
WARNING: Electronics control by switching ‘n’ (neutral), in some instances neutral
terminations will be at 230 volts with respect to earth.
7.1 The Speediboil incorporates an electronic scale conditioning function which
will reduce the rate of scale deposition in hard water areas. However, some
deposits may still occur in the storage tank; these should be periodically
removed.
7.2 The amount of usage of the unit will also determine the quantity of scale build
up. A regular inspection of the tank every 6 to 12 months will provide longer
life of the product and optimum performance (removal of the steam plate
assembly will give access to the storage tank) .
7.3 The front cover and spout will require a periodic wipe to clean any marks/
splashes from use.
7.0 MAINTENANCE