Technical data
7
Table 2 - Dimensions and Performance
Fig 4 - General Dimensions
NOMINAL
CAPACITY
(litres)
TYPE DIMENSIONS (mm) COIL
HEATING TIME
DIRECT (mins)
Direct Indirect A B C D
RATING
(kW)
HEAT
UP TIME
(mins)
HOT WATER
DRAW-OFF
(Litres ) to
40°C
100
306 493 784
97
99
100
315 354 500 784 15.2 24
120
306 616 906
108
121
120
315 354 616 906 15.4 24
150
306 800 1090
135
152
150
315 354 800 1090 15.9 29
170
306 925 1216
157
173
170
315 354 927 1216 17.3 30
210
306 1184 1474
199
215
210
315 354 1184 1474 19.2 34
250
306 1437 1726
240
257
250
315 354 1439 1726 18.6 42
300
306 1751 2040
273
310
300
315 354 1754 2040 18.8 49
NOTES:
1. Indirect cylinders tested in conformance with BS EN 12897:2006
2. Heat up time from cold through 45°C, with a primary ow rate of 15L/min at 80°C ± 2°C
3. Direct heating times assume use of lower element only, from cold through 45°C
4. “Cold” is assumed to be 15°C