Specifications

4
IMPORTANT : PLEASE READ AND UNDERSTAND THESE INSTRUCTIONS BE-
FORE INSTALLING THE PREMIER PLUS SYSTEMFIT WATER HEATER. INCOR-
RECT INSTALLATION MAY INVALIDATE GUARANTEE.
THE PREMIER PLUS MUST BE INSTALLED BY A COMPETENT INSTALLER IN
ACCORDANCE WITH BUILDING REGULATION G3 (ENGLAND AND WALES),
TECHNICAL STANDARD P3 (SCOTLAND) OR BUILDING REGULATION P5
(NORTHERN IRELAND).
2.1 COMPONENT CHECK LIST
Before commencing installation check that all the components for your Premier Plus SystemFit
unit are contained in the package. The following components are supplied with your Premier Plus
unit :
• Factory tted immersion heater (s) and thermal controls
Cold Water Combination Valve (comprises Pressure Reducing Valve,
Strainer, Check Valve)(supplied loose)
Factory tted Expansion core unit (comprises Expansion Valve and Check Valve)
Potable water Expansion Vessel (supplied loose)
Factory tted Temperature/Pressure Relief Valve (set at 90
o
C/10bar)
Tundish
Factory tted Indirect Thermostat and Thermal Cut-out
2 x 2-Port Motorised Valve
Primary circulating pump
Lock-shield ow balancing valve
Automatic bypass valve
Primary circuit lling loop
Primary circuit Pressure Gauge
Automatic air vent
Primary circuit expansion vessel (12 litre) (supplied loose)
CH/DHW programmer and room temperature sensor (supplied loose)
2.2 SITING THE PREMIER PLUS SYSTEMFIT
The Premier Plus SystemFit unit must be vertically oor mounted. It can be placed anywhere con-
venient provided the discharge pipe(s) from its safety valves can be correctly installed. Areas that
are subject to freezing must be avoided. Ensure that the oor is of sufcient strength to support
the “full” weight of the unit (refer to Dimensions Tables on pages 30 and 31 for unit weights). Pipe
runs should be kept as short as possible for maximum economy. Access to associated controls,
immersion heaters and indirect controls (Note: indirect controls housing hinges open to the left
hand side) should be possible for servicing and maintenance of the system.
To aid installation the Premier Plus SystemFit is provided with lifting points located in the base
and top mouldings. A oor template is also provided to aid positioning.
2
General Requirements