Specifications
4
IMPORTANT : PLEASE READ AND UNDERSTAND THESE INSTRUCTIONS BE-
FORE INSTALLING THE PREMIER PLUS SYSTEMFIT WATER HEATER. INCOR-
RECT INSTALLATION MAY INVALIDATE GUARANTEE.
THE PREMIER PLUS MUST BE INSTALLED BY A COMPETENT INSTALLER IN
ACCORDANCE WITH BUILDING REGULATION G3 (ENGLAND AND WALES),
TECHNICAL STANDARD P3 (SCOTLAND) OR BUILDING REGULATION P5
(NORTHERN IRELAND).
2.1 COMPONENT CHECK LIST
Before commencing installation check that all the components for your Premier Plus SystemFit
unit are contained in the package. The following components are supplied with your Premier Plus
unit :
• Factory tted immersion heater (s) and thermal controls
• Cold Water Combination Valve (comprises Pressure Reducing Valve,
Strainer, Check Valve)(supplied loose)
• Factory tted Expansion core unit (comprises Expansion Valve and Check Valve)
• Potable water Expansion Vessel (supplied loose)
• Factory tted Temperature/Pressure Relief Valve (set at 90
o
C/10bar)
• Tundish
• Factory tted Indirect Thermostat and Thermal Cut-out
• 2 x 2-Port Motorised Valve
• Primary circulating pump
• Lock-shield ow balancing valve
• Automatic bypass valve
• Primary circuit lling loop
• Primary circuit Pressure Gauge
• Automatic air vent
• Primary circuit expansion vessel (12 litre) (supplied loose)
• CH/DHW programmer and room temperature sensor (supplied loose)
2.2 SITING THE PREMIER PLUS SYSTEMFIT
The Premier Plus SystemFit unit must be vertically oor mounted. It can be placed anywhere con-
venient provided the discharge pipe(s) from its safety valves can be correctly installed. Areas that
are subject to freezing must be avoided. Ensure that the oor is of sufcient strength to support
the “full” weight of the unit (refer to Dimensions Tables on pages 30 and 31 for unit weights). Pipe
runs should be kept as short as possible for maximum economy. Access to associated controls,
immersion heaters and indirect controls (Note: indirect controls housing hinges open to the left
hand side) should be possible for servicing and maintenance of the system.
To aid installation the Premier Plus SystemFit is provided with lifting points located in the base
and top mouldings. A oor template is also provided to aid positioning.
2
General Requirements