Specifications
Multipoint
9
IMPORTANT - INSTALLATION TO BE DONE BY A COMPETENT
INSTALLER
4.1 The appliance must be mounted on a at surface, which covers the full width
and length of the backplate. It is important that the wall surface is at otherwise
difculty may be encountered when tting the cover.
4.2 Ensure that the hand wash is positioned over the basin, because if the PRD
operates water will eject from the bottom of the appliance.
4.3 The outlet of the hand wash acts as a vent and MUST NOT be connected to
any form of outlet ow control, or any other tting not recommended by Santon.
4.4 DO NOT t the hand wash to the wall and tile up to the case. It must be tted
on to a nished at and even wall surface. This allows removal for servicing.
4.5 The control knob is an integral part of the cover - do not attempt to
remove it.
4.0 CONSIDERATIONS BEFORE FITTING
4.6 Position the unit above the
basin so that the spray will be
contained within the basin and at a
convenient height for hand washing
see Figure 4.
4.7 A clearance of at least 130mm
above and below the unit should be
allowed for access to the cover
screws.
4.8 Cable entry can be from the rear
(preferred) or from the bottom. The
backplate has cut-out position to
suit size of cable. When opting
for bottom entry make the cut-out to
suit the cable before tting the
backplate to the wall -see Figure 5.
Figure 4 Handwash position over basin (or sink)
200
mm
PRD
Outlet
Typical arrangement
Isolating stop valve
Main water supply
(Use rear entry when
it is possible)
130mm
min
Make cut-out
using sharp
knife
Figure 5 Bottom entry cable cut-out