Specifications
Multipoint
15
8.1 In the unlikely event of a problem, consult the trouble-shooting chart below.
8.2 If you are unable to remedy the problem, CONTACT YOUR INSTALLER
in the rst instance.
IMPORTANT
8.3 Do not attempt any electrical or plumbing work unless you are competent to
do so.
8.4 If you still cannot solve the problem, please contact Santon.
INSPECTION
8.5 It is advisable that, in the interests of safety, the handwash and its electrical
installation is checked by a competent electrician, at least every two years.
8.0 FAULT FINDING
SYMPTOM POSSIBLE CAUSE REMEDY
A. Water supply turned off Turn on water supply
B. Unit frozen Turn OFF ELECTRICITY at isolating switch
and contact installer. DO NOT USE THE
HANDWASH.
C. Spout blocked Clean sprayplate - see 9.2
D. Filter blocked Clean filter
E. Electrical power to
appliance off
A. Torx adjusting screw at Turn torx screw clockwise until temperature
wrong setting is comfortable
B. Water flow too high Turn torx screw clo
ckwise until temperature
is comfortable
C. Poor flow Check inlet pressure
A. Torx adjusting screw at Turn torx screw fully anticlockwise to increase
wrong setting flow and lower temperature
B. Spout partially blocked
C. Isolating valve not fully Open isolating valve
open
D. Filter blocked Clean filter
A. Spout blocked
Push plastic plunger up and back in place.
pressure relief
B. Spout not blocked Cal
l a service engineer, as there may be a
problem with internal parts.
Ensure that the electricity supply to the
appliance is switched on
with valve open
device
1. No water flows
2. Water too cold
3. Water too hot
4. Water runs from
Clean sprayplate - see 9.2
Clean sprayplate - see 9.2