Specifications
14
NOTE: The rst operation of the hand wash is intended to ensure the heater
unit contains water before the appliance is switched on.
7.1 Before turning on the electricity and mains water to the hand wash, ensure the
torx adjusting screw is turned fully anti-clockwise - see gure 15.
7.2 Turn on the main water supply at the isolating stop valve.
7.3 Place hand in front of appliance sensor to activate solenoid.
7.4 When water ows constantly from spout turn torx adjusting screw to an
acceptable level of ow, (You may have to place your hand in front of sensor
to keep water owing) adjust further for acceptable heat.
7.5 Leave torx adjusting key with customer.
7.0 COMMISSIONING
Figure 15 Adjusting screw