User manual
User manual
SANTEC IP cameras
_________________________________________________________________________________
- 98 -
Security Name:
The max. length of the security name is 32 digits (A-Z, a-z, 0-9).
The following special characters are valid: ! # $ % & ´- . @ ^_ ~
Authentication Type:
2 authentication types are available: MD5 and SHA.
Select SHA as the more secure authentication method.
Authentication Password:
The authentication password must be at least 8 digits long (A-Z, a-z, 0-9). They
will be displayed as dots for security reasons.
The following special characters are valid: ! # $ % & ´- . @ ^_ ~
Encryption Type:
2 encryption types are available: DES and AES.
Select AES as the more secure method.
Encryption Password:
The encryption password must be at least 8 digits long (A-Z, a-z, 0-9). They will
be displayed as dots for security reasons.
The following special characters are valid: ! # $ % & ´- . @ ^_ ~
Note:
The encryption password may also be left blank. However, this means that the
messages will not be encrypted.
Traps for SNMP v1 / v2:
Traps are used by the IP camera to send massages to a management system for important
events or status changes.
Enable traps:
Check the box to activate trap reporting.
Note:
Traps can only be activated, if at least one SNMP function has been activated
before (v1, v2 and/or v3).
Trap address:
Enter the IP address of the management server.
Trap community:
Enter the community to use when sending a trap message to the management
system.
Trap Option: Warm start:
A warm start SNMP trap signifies that the SNMP device, i.e. the IP camera, performs a
software reload.
Click on <Save>.