User manual

User manual
SANTEC IP cameras
_________________________________________________________________________________
- 16 -
SNC-6302, SNC-6312IRH, SNC-6315IRH, SNC-6323IRH:
Camera inside view:
No.
Connector
Pin
Definition
Remarks
1
Reset Button
-
Restore to factory default
Keep camera connected to power.
Use a pointed device to press onto the reset button and
hold it for approx. 1 sec.
Release the button and wait approx. 1 sec.
Press and hold the reset button for approx. 30 sec.
The camera is now restored to factory default settings.
2
BNC
-
Analogue video output
3
Alarm I/O
1
GND (Input -)
Alarm connection
2
Input +
3
Output -
4
Output +
4
Audio I/O
1
Output (L)
Two-way audio transmission
2
Output (R)
3
GND
4
Input
5
Power
DC 12V
1
Power
Power connection
2
Reserved
3
GND
AC 24V
1
Power-1
2
Earth GND
3
Power-2
6
RJ-45
-
10/100 Mbps Ethernet / PoE