User manual
User manual
SANTEC IP cameras
_________________________________________________________________________________
- 105 -
Note:
The IR function cannot be set to <auto> mode if this triggered action is enabled.
Also refer to chapter “2.5.5 IR function” for further details.
Send alarm message by FTP/e-mail:
The administrator can select whether to send an alarm message by FTP and/or
e-mail when an alarm is triggered.
Upload image by FTP/e-mail:
Select this item and the administrator can assign a FTP site or an e-mail address and
configure various parameters. When the alarm is triggered, event images will be
uploaded to the appointed FTP site or e-mail address.
The <Pre-trigger buffer> function allows users to check what happened to cause the
trigger. The <Pre-trigger buffer> frame rate can be pre-determined.
The <Post-trigger buffer> allows to store a certain amount of images after the alarm
input is triggered.
Check the box <Continue image upload> to upload the triggered images during
certain time or keep uploading until the trigger is off. Select <Upload for … sec> and
enter the duration in the field (1-99999). The alarm images are stored on the FTP site.
Select <Upload during the trigger active> to make the images keep being uploaded to
FTP until the alarm trigger is released. Set the image frequency as the upload frame
rate (1-15 frames).
Note on FTP:
Make sure the FTP configuration has been completed.
Also refer to chapter 2.3.4.2 FTP server” for further details.
Note on e-mail:
Make sure the SMTP configuration has been completed.
Also refer to chapter “2.3.4.1 Mail Server” for further details.
Send HTTP notification:
Check this item to determine the HTTP address and to specify the parameters for
event notifications in case of a triggered alarm. When an alarm is triggered, the
notification is sent to the specified HTTP server.
Example:
If the custom parameter is set as ”action=1&group=2” and the HTTP server name is
”http://192.168.1.10/alarm.php”, the notification will be sent to HTTP server as
”http://192.168.1.10/alarm.php?action=1&group=2” when an alarm is triggered.