Install Instructions
6
Santa Fe ULTRA120V Installation & Operation Instructions Santa-Fe-Products.com | 800.533.7533
The Santa Fe Ultra120V plugs into a common grounded 115 VAC outlet. The device draws 5.8 Amps at
80°F and 60% RH. Locate the dehumidier in an area where the cord’s length (9') easily reaches a 115 VAC
electrical outlet with a minimum of 15 Amp circuit capacity. If used in an area that may become wet, a GFCI
protected circuit is recommended. Consult local electrical codes for further information.
Santa Fe oers a variety of control devices for use with the Santa Fe Ultra120V. The control is to be located
remotely from the dehumidier and placed in the space to be conditioned. A low voltage (24 Volt) control MUST
be used with the Santa Fe Ultra120V and MUST be connected with low voltage (18-22 gauge) thermostat
wire.
ELECTRICAL REQUIREMENTS
CAUTION!CAUTION!
DO NOT ALLOW THE 24V TERMINAL TO CONTACT THE COM TERMINAL ON THE SANTA FE
ULTRA120V OR DAMAGE TO THE TRANSFORMER WILL RESULT.
Electrical Precautions
• Do not install the control where it may not accurately sense the relative humidity such as near HVAC
supply registers, near exterior doors, on an outside wall, near a window, or near a water source.
• The terminals on the Santa Fe Ultra120V and the control are labeled to prevent confusion.
• Be sure to consult the electrical schematic in the CONTROLS Section (Page 11) of this manual or inside
the access panel of the Santa Fe Ultra120V before making control connections.
WARNING!WARNING!
THE REMOTE CONTROLS OF THE SANTA FE ULTRA120V ARE POWERED BY A LOW VOLTAGE CIR-
CUIT (24 VAC) AND MUST NEVER CONTACT OR BE CONNECTED TO A HIGH VOLTAGE CIRCUIT.
CAUTION!CAUTION!
SOME OF THE TERMINALS ON THE SANTA FE ULTRA120V MAY NOT BE USED WITH CERTAIN
CONTROLS AND SHOULD BE LEFT UNCONNECTED.
Wiring Diagram