Install Instructions

4
Santa Fe ULTRA120V Installation & Operation Instructions Santa-Fe-Products.com | 800.533.7533
Important Precautions
The device is designed to be installed indoors in a space that is protected from rain and ooding.
• Install the unit with enough space to access the front panel for maintenance and service.
• Avoid directing the discharge air at people. The dehumidier should be used in the upright position.
If used near a water source, be certain there is no chance the unit could fall into the water or get splashed and
that it is plugged into a dedicated circuit and Ground Fault Circuit Interrupter (GFCI) protected outlet.
• DO NOT use the dehumidier as a bench or table.
DO NOT place the dehumidier directly on structural building members without vibration absorbers or unwanted
noise may result. Place the Santa Fe Ultra120V on supports to raise the base of the unit.
A drain pan with a oat switch MUST be placed under the dehumidier if installed above a living area or above
an area where water leakage could cause damage.
Location Considerations
Allow sucient clearance to handle the unit’s overall dimensions as well as the necessary return and supply
ductwork to the unit.
• Allow sucient clearance for lter removal and to prevent airow obstruction.
Electrical service access will require the removal of the front panel. Allow sucient clearance on this side of the unit.
Locate the dehumidier in an area where the cord’s length (9') easily reaches a 115 VAC electrical outlet with a
minimum of a 15 Amp circuit capacity.
• Locate the dehumidier in an area where eld wiring the control (low voltage) to the unit will be possible.
It is recommended that a backdraft damper be used in the discharge duct of the Santa Fe Ultra120V, especially
when connecting to the supply ducting system. The backdraft damper prevents supply air from counter
owing through the Santa Fe Ultra120V when it is not operating. The dehumidier’s location should be chosen to
allow installation of this accessory if necessary.
DO NOT hang the
Santa Fe Ultra120V
from its cabinet.
Allow for proper
routing and drainage
of needed drain pipes.
70°F and 60% RH
90 pints/day
6.0 Pints/kWh
Shipping
24
49
21
138 lbs.
6" Fresh Air Intake (Optional)
8" Return Air Duct
8" Supply Air Duct #1
Front View
8" Supply Air Duct #2 (Optional)
8" Duct Cover (Optional)
DEHUMIDIFIER SET UP