User Guide

9
800.533.7533 | Santa-Fe-Products.com Santa Fe Advance90 / Advance120 Installation & Operation Instructions
Ducting To Finished Areas (Optional)
Passive Return Vent
1
1
2
Optional Wall
Mount Dehumidistat
(mounts on opposite wall in finished area)
3
Supply Grill
4
Supply/Discharge
Duct Work
Installation of a
Santa Fe Compact2 With a
Supply Duct Kit Only
F
i
n
i
sh
e
d
Ar
e
a
Un
f
ini
s
h
e
d
A
rea
3
1
2
4
Installation of a Supply Kit Only
Return/Intake
Duct Work
1
6
1
Return Grill
3
Supply Grill
Supply/Discharge
Duct Work
Installation of a
Santa Fe Compact2 With a
Supply Duct Kit Only
Unfinished Area
F
i
n
i
sh
e
d
Ar
e
a
Un
f
ini
s
h
e
d
A
rea
1
Optional Wall Mount
Dehumidistat (mounts on
opposite wall in finished area)
2
Passive Return Vent*
5
4
6
5
2
3
4
Installation of a Supply and Return Duct Kit
Recommended Installations
Place the Santa Fe dehumidier in the unnished area
of the basement, near a drain access (condensate will
drain via gravity or with an optional pump kit).
Using the supply duct collar, supply the dry air from
the dehumidier into a large, open area in the
nished section of the basement.
Place a return grill / passive vent on the other side of
the wall that separates the nished and unnished
areas. This will allow for a circular air flow
throughout the basement.
The passive grill will prevent the unnished room
from being placed under a negative pressure and
also allow the dehumidier to focus on keeping the
unnished area dry as well.
The onboard dehumidistat control can be used
on the unit for this application or a 120 volt
dehumidistat can be placed in the nished basement
as well (we recommend using an electrician to run
the wiring).
Be sure to keep all doors open to any other rooms in
the basement to help with proper air circulation
(bedrooms, bathrooms, etc.)
Place the Santa Fe dehumidier in the unnished area
of the basement, near a drain access (condensate will
drain via gravity or with an optional pump kit).
Using the supply and return duct kit, supply the dry
air from the dehumidier into a large, open area of the
nished basement. Use the return duct kit to draw air
back through the dehumidier.
Be sure the return and supply are at least 10 feet away
from each other for proper air flow throughout the
basement. Add a passive grill between the nished
and unnished areas (*or have a 2” gap under the door
separating the two rooms). This will help keep the
unnished area dry as well.
Use the 120 volt, wall mounted dehumidistat for this
installation for proper run time on the dehumidier (we
recommend using an electrician to install the separate
120 volt control).
Be sure to keep all doors open to any other rooms in
the basement to help with proper air circulation
(bedrooms, bathrooms, etc.)