User Guide
4
Santa Fe Advance90 / Advance120 Installation & Operation Instructions Santa-Fe-Products.com | 800.533.7533
Items Included in Box:
• Santa Fe Advance Dehumidier
• Santa Fe Advance Dehumidier Installation & Operation Instructions
• Santa Fe Advance Dehumidier Leveling Feet
• 8’ Drain Hose
• Drain Adapter
• MERV-13 Filter (Dimensions: 1.75” x 14.00” x 17.50”)
Important Precautions
• Do not install the Santa Fe Advance dehumidier with the intake or exhaust of the unit within one foot (12”) of a wall or other
obstruction. Avoid directing the discharge air at people. The dehumidier should be used in the upright position.
• Do not place the unit where curtains or debris can be drawn into the intake and restrict airflow.
• The device is designed to be installed indoors in a space that is protected from rain and flooding.
• Do not operate in standing water or place the unit near open water. If used near a water source; be certain there is no
chance the unit could fall into the water or get splashed and that it is plugged into a dedicated circuit and Ground Fault
Circuit Interrupter (GFCI) protected outlet.
• Install the unit with enough space to access all sides for maintenance and service. The top “L” shaped panel needs to
be removed in order to do repairs.
• DO NOT use the dehumidier as a bench or table.
• DO NOT place the dehumidier directly on structural building members without vibration absorbers or unwanted noise
may result. Place the Santa Fe Advance dehumidier on supports to raise the base of the unit.
Location Considerations
• Locate the dehumidier near a suitable drain
(8’ drain hose included). Allow for proper
drainage and routing of needed drain pipes.
• Locate the dehumidier in an area where the
cord’s length (9’) easily reaches a 115 VAC
electrical outlet with a minimum of a 15 Amp
circuit capacity.
• The unit is designed to operate while level. If
the unit is placed on an unlevel surface, refer
to section below (Installing Leveling Feet).
Failure to level the unit may result in leakage or
improper drainage.
• The unit should be suspended with a hang kit
from the floor joists if there is any possibility
of flooding. A flooded unit is not covered by
warranty. Feet will be installed as a securing
measure after the hang kit is put on the
dehumidier. DO NOT hang the Santa Fe
Advance dehumidier from its’ cabinet.
• Allow sufcient clearance to handle the unit’s overall dimensions as well as any optional return and supply ductwork to the unit.
• Allow sufcient clearance for lter removal and to prevent airflow obstruction.
• Electrical service access will require the removal of the top “L” shaped panel. Allow sufcient clearance around the unit.
Installing Leveling Feet
• Lay down a protective pad (pillow, blanket, etc.).
• Carefully turn unit onto side.
• Install leveling feet and adjust to the desired position to ensure unit is level for proper drainage.
• Carefully bring unit to upright position.
• Wait a minimum of 10 minutes before operating.
Dehumidier Set Up
9' POWER CORD
TOP VIEW
MINIMUM
CLEARANCE
FOR PROPER
AIR FLOW OF
INTAKE AIR
14"
RETURN AIR
SUPPLY AIR
A
B
A
DRAIN
ACCESS
MINIMUM CLEARANCE
FOR PROPER AIR FLOW
OF EXHAUST AIR
B
14"
MINIMUM
CLEARANCE
FOR PROPER
AIR FLOW OF
EXHAUST AIR
14"
B
12"
MINIMUM
CLEARANCE
FOR FILTER
REMOVAL
CAUTION! REMOVE COMPRESSOR SHIPPING TIE FROM THE UNIT. FAILURE TO REMOVE
SHIPPING TIE WILL CAUSE EXCESS VIBRATION TO BE TRANSMITTED TO THE FRAME.
The Santa Fe Advance dehumidier uses a compressor to power the refrigeration system. To protect
the compressor and refrigeration system during shipping a plastic tie wrap secures it to the units
frame. Remove the tie wrap by cutting the tie wrap and pulling from the unit as shown. After removing
tie wrap, insert plastic plugs provided into the holes.