Electrical Requirements
Wiring Schematic
The Santa Fe Advance dehumidier plugs into a common grounded 115VAC outlet. The Advance90 draws 5.7 Amps at
80°F and 60% RH. The Advance120 draws 7.3 Amps at 80°F and 60% RH. Locate the dehumidier in an area where the
cord’s length (9') easily reaches a 115 VAC electrical outlet with a minimum of 15 Amp circuit capacity. If used in an area
that may become wet, a GFCI protected circuit is recommended. The unit should not be used in areas prone to flooding.
Consult local electrical codes for any further information.
An optional remote dehumidistat is available for use with the Santa Fe Advance dehumidier and is to be located remotely
from the dehumidier.
CAUTION!
ELECTRICAL SHOCK HAZARD: Electrical power must be present to perform some tests. These tests should be
performed by a qualied service person.