Ducting To Finished Areas (Optional)
• Place the Santa Fe Compact70 in the unnished area
of the basement, near a drain access (condensate will
drain via gravity or with an optional pump kit).
• Using the supply duct collar, supply the dry air from
the dehumidier into a large, open area in the nished
section of the basement.
• Place a return grill / passive vent on the other side of
the wall that separates the nished and unnished
areas. This will allow for a circular air flow throughout
the basement.
• The passive grill will prevent the unnished room from
being placed under a negative pressure and also allow
the dehumidier to focus on keeping the unnished
area dry as well.
• The onboard dehumidistat control can be used on the
unit for this application or a 120 volt dehumidistat
can be placed in the nished basement as well (we
recommend using an electrician to run the wiring).
• Be sure to keep all doors open to any other rooms in the
basement to help with proper air circulation (bedrooms,
bathrooms, etc.)
• Place the Santa Fe Compact70 in the unnished area of
the basement, near a drain access (condensate will drain
via gravity or with an optional pump kit).
• Using the supply and return duct kit, supply the dry air
from the dehumidier into a large, open area of the n-
ished basement. Use the return duct kit to draw air back
through the dehumidier.
• Be sure the return and supply are at least 10 feet away
from each other for proper air flow throughout the
basement. Add a passive grill between the nished and
unnished areas (*or have a 2” gap under the door
separating the two rooms). This will help keep the
unnished area dry as well.
• Use the 120 volt, wall mounted dehumidistat for this
installation for proper run time on the dehumidier
(we recommend using an electrician to install the
separate 120 volt control).
• Be sure to keep all doors open to any other rooms in the
basement to help with proper air circulation (bedrooms,
bathrooms, etc.)
Passive Return Vent
1
1
2
Optional Wall
Mount Dehumidistat
(mounts on opposite wall in finished area)
3
Supply Grill
4
Supply/Discharge
Duct Work
Installation of a
Santa Fe Compact2 With a
Supply Duct Kit Only
Unfinished Area
Finished Area
F
i
n
i
sh
e
d
A
r
e
a
Un
f
ini
s
h
e
d
A
rea
3
4
1
2
Installation of a Santa Fe Compact70
With a Supply Kit Only
Return/Intake
Duct Work
1
6
1
Return Grill
3
Supply Grill
Supply/Discharge
Duct Work
Installation of a
Santa Fe Compact2 With a
Supply Duct Kit Only
Unfinished Area
Finished Area
F
i
n
i
sh
e
d
A
r
e
a
Un
f
ini
s
h
e
d
A
rea
1
3
4
2
5
Optional Wall Mount
Dehumidistat (mounts on
opposite wall in finished area)
2
Passive Return Vent*
5
4
6
Installation of a Santa Fe Compact70
With a Supply and Return Duct Kit
Recommended Installations