User Guide

9
800.533.7533 | Santa-Fe-Products.com Santa Fe ULTRA98/ULTRA120 Installation & Operation Instructions
Recommended HVAC System Installation
DUCTING TO HVAC SYSTEMS
The recommended installation draws air from a dedicated indoor air return and ducts the supply of the
dehumidier to the air supply of the existing HVAC system. Utilize the optional fresh air ventilation duct to
provide outside air.
• Install a dedicated 10" air return for the Santa Fe Dehumidier from a central area of the structure.
Install an insulated duct from outside to the 6" collar of the Santa Fe Dehumidier to provide fresh air
ventilation (optional).
Duct the supply of the Santa Fe Dehumidier to the supply of the existing HVAC system with a backdraft
damper.
If the existing system has multiple returns, instead of installing a dedicated return to the Santa Fe
Dehumidier, it is possible to select one to disconnect from the existing HVAC system and use it for the
dedicated Santa Fe Dehumidier return. Select a return from a central location in the house that is always
open to the rest of the structure. DO NOT use a return from a room where doors are kept closed.
DO NOT locate return in a bathroom or kitchen.
Control should be located remotely from the dehumidier and placed in a central location.
Please visit our website at www.Santa-Fe-Products.com/install-options/ for more installation options.
Santa Fe
Supply
Air Handler
HVAC Supply
Dedicated Ultra-Aire 90 Return to A/C Supply
HVAC Return
Fresh Air Intake
(Optional)
Motorized
Damper
Indoor
Air Return
Backdraft
Damper
Dedicated Santa Fe Return to HVAC Supply