User Guide
4
Santa Fe Classic Installation & Operation Instructions Santa-Fe-Products.com | 800.533.7533
Items Included in Box:
• Santa Fe Classic Dehumidier
• Santa Fe Classic Installation & Operation Instructions
• MERV-13 Filter (Dimensions: 1.75” x 15.50” x 19.50”)
• Drain Hose Attached to Dehumidier (6')
Important Precautions
• Do not install the Santa Fe Classic with the intake or exhaust of the unit within 1' of a wall or other obstruction. Avoid
directing the discharge air at people. The dehumidier should be used in the upright position.
• Do not place the unit where curtains or debris can be drawn into the intake and restrict airflow.
• The device is designed to be installed indoors in a space that is protected from rain and flooding.
• Do not operate in standing water or place the unit near open water. If used near a water source; be certain there is no
chance the unit could fall into the water or get splashed and that it is plugged into a dedicated circuit and Ground Fault
Circuit Interrupter (GFCI) protected outlet.
• Install the unit with enough space to access the front panel (label side) and the discharge air flow side of the unit for
maintenance and service. The front, label side panel needs to be removed in order to do repairs.
• DO NOT use the dehumidier as a bench or table.
• DO NOT place the dehumidier directly on structural building members without vibration absorbers or unwanted noise
may result.
Location Considerations
• Locate the dehumidier near a suitable drain
(6' drain hose included). Allow for proper
drainage and routing of needed drain pipes.
• Locate the dehumidier in an area where the
cord’s length (9') easily reaches a 115 VAC
electrical outlet with a minimum of a 15 Amp
circuit capacity.
• The unit is designed to operate while level.
Failure to level the unit may result in leakage
or improper drainage.
• A flooded unit is not covered by warranty.
• Allow sufcient clearance to handle the unit’s
overall dimensions as well as any optional
return and supply ductwork to the unit.
• Allow sufcient clearance for lter removal
and to prevent airflow obstruction.
• Electrical service access will require the
removal of the front panel. Allow sufcient
clearance around the unit.
Dehumidier Set Up
When unpacking make sure to remove corrugated shipping cardboard from top of unit.