SANTA FE CLASSIC Installation & Operation Instructions The Santa Fe Classic has a vertical configuration Serial Number and its’ flow-down design performs exceptionally Install Date well in basements. The high capacity blower on the unit moves air in a way that no small conventional Sold By unit can. The Classic’s optional condensate pump and ducting kits provide the flexibility necessary for any application. Patent: thermastor.com/patents Santa-Fe-Products.com | 800.533.
Table of Contents Safety Instructions...................................................................................3 Intended Applications.................................................................................3 Registrations...............................................................................................3 Dehumidifier Set Up..................................................................................4 Items Included In Box....................................................
Safety Instructions READ THE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND OPERATING THIS DEVICE. PROPER ADHERENCE TO THESE INSTRUCTIONS IS ESSENTIAL TO OBTAIN MAXIMUM BENEFIT FROM YOUR SANTA FE DEHUMIDIFIER. WARNING! THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. FAILURE TO HEED THEM CAN RESULT IN SERIOUS INJURY OR DEATH. CAUTION! THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. FAILURE TO HEED THEM CAN RESULT IN INJURY OR MATERIAL PROPERTY DAMAGE.
Dehumidifier Set Up When unpacking make sure to remove corrugated shipping cardboard from top of unit. Items Included in Box: • Santa Fe Classic Dehumidifier • Santa Fe Classic Installation & Operation Instructions • MERV-13 Filter (Dimensions: 1.75” x 15.50” x 19.50”) • Drain Hose Attached to Dehumidifier (6') Important Precautions • Do not install the Santa Fe Classic with the intake or exhaust of the unit within 1' of a wall or other obstruction. Avoid directing the discharge air at people.
Drain Installation The Santa Fe Classic generates condensate. A 6' condensate hose comes attached to the unit. Be sure the hose is not kinked or otherwise restricted so water can pass through the hose freely. If the Santa Fe Classic is located too far from the floor drain and the provided hose does not reach, you may use a 1/2" PVC rigid pipe to extend the drain. Rigid PVC tubing is readily available from your local hardware store. Be sure the extension is at a downward slope to the drain.
Operation Humidity Control Adjustment The humidity control is an adjustable switch that turns the dehumidifier on and off. It turns on when the relative humidity (RH) rises to the dial set point. It turns off when the RH is within ±5% of the set point.
Air Filtration The Santa Fe Classic is equipped with a MERV-13 air filter (89-90% ASHRAE dust spot). An optional MERV-11 filter is available at www.ThermastorFilters.com. The MERV-13 filter should be checked and replaced every three to six months. Operating the unit with a dirty filter will reduce dehumidifier capacity and efficiency. DO NOT operate the unit without the standard MERV-13 or optional MERV-11 filter. Filter non-compliance voids the product warranty.
Ducting To Finished Areas (Optional) Attaching Duct Collars Return Air Inlet Hood The return air inlet hood has an 8” and 6” diameter collar. The 8” collar is the main return collar and must be used. The 6” collar is optional and can be left closed to draw air from another location. Supply Air Outlet The 8” supply collar is included in the return duct kit and also sold separately. Ductable Inlet Exhaust Collar 8 Santa Fe Classic Installation & Operation Instructions Santa-Fe-Products.com | 800.533.
Ducting To Finished Areas (Optional) Recommended Installations 1 Installation of a Santa Fe Classic With a Supply Kit Only 3 1 Finish e d Area 1 Passive Return Vent Installation of a Santa Fe Classic With a Supply and Return Duct Kit 4 1 2 2 a is h n i nf e re dA U 3 Supply Grill 4 Supply/Discharge Duct Work Mount Dehumidistat (mounts on opposite wall in finished area) 2 Optional Wall • Place the Santa Fe Classic in the unfinished area of the basement, near a drain access (condensate wi
Service - Troubleshooting CAUTION! TROUBLESHOOTING SHOULD BE PERFORMED BY A QUALIFIED HVAC TECHNICIAN. Symptom Possible Reason Fan is not running. Dehumidification or fan is being called for. 1. L oose connection in fan circuit. 2. O bstruction prevents fan impeller rotation. 3. Defective fan. 4. Defective fan relay. Low dehumidification 1. D efrost thermostat loose capacity (evaporator or defective. is frosted 2. Low refrigerant charge. continuously).
Service - Troubleshooting WARNING! CAUTION! TROUBLESHOOTING SHOULD BE PERFORMED BY A QUALIFIED HVAC TECHNICIAN. Symptom Possible Reason Neither fan nor compressor running. Dehumidification is being called for. 1. D ehumidifier unplugged or no power to outlet. 2. H umidity control set too high. 3. Loose connection in internal or control wiring. 4. D efective compressor relay. Compressor is not running. Dehumidification is being called for. Fan is running. 1.
Electrical Requirements The Santa Fe Classic plugs into a common grounded 115VAC outlet. The device draws 6.4 Amps at 80°F and 60% RH. Locate the dehumidifier in an area where the cord’s length (9') easily reaches a 115 VAC electrical outlet with a minimum of 15 Amp circuit capacity. If used in an area that may become wet, a GFCI protected circuit is recommended. The unit should not be used in areas prone to flooding. Consult local electrical codes for any further information.
Warranty Limited Warranty.
Santa Fe Classic Installation & Operation Instructions Santa-Fe-Products.com | 800.533.
800.533.7533 | www.Santa-Fe-Products.
DEHUMIDIFIERS Santa-Fe-Products.com 800.533.