Install Instructions

Pump Kit
Part No. 4022220
Parts Included:
1. Condensate Pump with Cord (120V)
2. (2) 8-18 x 3/4 Screws (Vertical
conguration only)
3. 3/8" x 20' Hose
4. Clamp
Tools Required:
Phillips Screw Driver
Level
Utility Knife
Additional materials will be
needed to elevate dehumidier
4
1
3
CAUTION!
BEFORE INSTALLING PUMP KIT, DISCONNECT DEHUMIDIFIER FROM ELECTRICAL
POWER AND DISCONNECT DRAIN HOSE IF PREVIOUSLY INSTALLED.
4201 Lien Rd Madison, WI 53704
TOLL-FREE 1-800-533-7533
www.thermastor.com
sales@thermastor.com
TS-201 6/20 Rev F
OVER
2
Vertical
configuration
only
Route hose as shown
into the hole farthest
from the dehumidier.
Pump Top View
Cut hose at 45 degree angle
and attach as shown.
Horizontal & Vertical Configuration
Step 1
: Route 9/16" hose
from the dehumidifier to the
condensate pump as shown.
Be careful not to kink the
hose. Trim hose to fit properly.
To help with proper drainage,
cut hose at 45 degree angle.