Server Monitoring - Notification
EN104L+(B) is equipped with features that will notify designated administrators with failure notifications via e-mail.
To setup failure notifications
, enter the following:
• SMTP Server IP Address - Enter the outgoing e-mail server IP address.
• E-mail Addresses - Enter the full e-mail addresses (e.g. bobjones@company.com
) of up to three administrators who are to be
notified when any of the above selected failures occur.
• Send Test E-mail - E-mail a test notification message to each address entered under E-mail Addresses above to ensure
notifications are received properly.
• Enable UPS – COM2 port of EN104L+(B) may be connected to a UPS’s monitoring port. In the event UPS is activated due to
power loss, EN104L+(B) will email the administrator(s) every minute until it is automatically shutdown in 5 minutes. For proper
function, Simple Signaling cable must be used.
• SNMP – When enabled, monitoring applications may receive EN104L+(B) status via. SNMP protocol.
• Temperature/Fan Monitoring – Temperature, CPU/Chassis fans may be monitored via. web administration. In addition, any
over-temp or fan failure status will be notified by email.
• RAID – PCI based RAID controller pass its array status to the event log, and will also trigger the email notification in case a disk
fails.
CAUTION: By default, temperature and fan monitoring are disabled. This is to prevent automatic system shutdown when unknown
motherboard is configured. EN104L+(B) OS must be able to communicate with the server monitoring chips (often referred to LM or I2C
sensors) in order to properly use this feature. Any unrecognized chips will result in self-shutdown and require special boot-up process for
proper OS boot.
To apply changes, click on Apply at the bottom of the screen. To undo changes, click on Cancel.