Dimensions Guide

EXTERNAL UNITS - SPECIFICATION SHEET
TECHNICAL SPECIFICATIONS
The Saniaccess2 is a 1/2 HP pump system used to install a half-bathroom up to 15 feet below the sewer line, or even up to 150 feet
away from a soil stack. It incorporates a macerating system which can handle human waste and toilet paper in residential applications.
The blade is made out of a hardened stainless steel material which eliminates the need for any service or replacement.
Discharges the waste through a
3
4" or 1" rigid pipe. A non-return valve is included on the discharge elbow assembly provided with the
system. This elbow can be rotated 360 degrees depending on the discharge installation.
Has been designed with a 1
1
2" vent connection on the side of the pump housing. All plumbing codes require connection to a vent system.
Please note that the vent system should be a two-way air vent as air needs to freely flow both ways. Note: The use of mechanical vents, air
admittance valves or similar devices is not permitted.
Must be connected to Saniflo’s 1.28 GPF rear discharge toilet. These toilets come in round and elongated
(ADA compliant) models. More technical information on page 5.
Will also discharge gray water from a sink. The wastewater will drain into the system via a 1
1
2" inlet which
is located on the side of the pump housing. Note that either side connection can be used for the vent or as an inlet.
Designed with two easy access service panels located on top of the pump.
On one side of the pump you can easily access the electrical components and the level sensor.
The other side allows access to the macerating blade for easy removal of foreign objects.
INSTALLATION BEHIND THE TOILET
INSTALLATION BEHIND THE WALL
Pump type: Macerator
Electrical: 120 V – 60 Hz / 4.5 Amps (Max)
Motor: 0.5 HP oil-filled thermally protected motor
Capacitor rating: 45 microfarad
Operating Temperature: 104 F° (110 F° Max.)
Power cord length: 51 inches
Noise level: 53 dBA (Lp) (measured at 3 ft.)
These toilets come in round and elongated
inlet
which
inlet which inlet
is located on the side of the pump housing. Note that either side connection can be used for the vent or as an inlet.
SANIACCESS2 • Part No. 081
Macerator
© SFA Sanifl o Inc.