users guide User guide
26
570-3C 80 880
570-3C 80 1200
570-3C 100 1100
570-3C 100 1500
570-3C 120 1900-80R/L
**
570-3C 150 2400-80R/L
**
570-3C 200 3200-80R/L
**
570-3C 250 4000-80R/L
**
Metric steel bars, product data
*) For diameter 80 mm and 100 mm, clamping over the damping mechanism is allowed.
**) Contact your Sandvik Coromant representative.
Article
D
th
Min rec.
clamping
length,
mm
Centre of
gravity
(COG), mm
Rec. over-
hang, mm
Max load
(with SL), N
Max
temp, CWeight, kg
Min length,
mm
Min length
Recommended overhang
(from insert tip to clamping)
Clamping (minimum
4 x dm
m
)
Centre of gravity (COG)
0-560* G3/4” 320 440 32 7000 75 360
0-800* G3/4” 320 605 44 7000 75 360
0-700* G3/4” 400 540 65 8000 75 415
0-1000* G3/4” 400 750 88 8000 75 415
840-1200 G3/4” 480 940 150 8000 75
1050-1500 G3/4” 600 1180 250 8000 75
1400-2000 G1” 800 1600 600 8000 75
1750-2500 G1” 1000 1950 1000 8000 75