s Instruction Manual

32
Driven tool holders
Operation instructions
Coolant requirements
Coolant lter max 50 μm (0.002 in).
DTH with internal coolant supply must not be
operated without coolant – Coolant must be turned
on and present before tool rotation. Running dry will
damage the internal seals. Seal damage is not cov
ered under warranty.
For machining cast iron, only external coolant design
should be used.
All DTH's with IC (internal coolant supply) are speci
ed for a max coolant pressure of 80 bars up to their
max. n (6000 rpm).
For drilling operations it is best to use internal coolant DTHs
with high pressure coolant.
Break in period
A break in period for DTH is essential for long life. Running
the DTH for a break in period removes the intensied friction
in all of the internal components and helps to distribute the
lubrication applied during assembly. Attention: Run DTH at
50% of max. output rpm for one hour without load. The max
rpm is specied on the DTH. For DTH with internal coolant,
apply coolant even during the break in period.