Owner's manual

Geometry selection guidelines
Material usage & curing temperature
CFRP
Material
Primary
- (medium-high T epoxy)
- Low temperature Epoxy
- Non structural skin (Epoxy-Phenolic)
Thermoplastic
With glass skin
With LSP
CD 854
0
0
0
-
-
X
CD 855 or
85/85C
0
X
-
X
X
CD 856
X
X
X
X
X
X
Cutting
conditions
MS LF
MS MF
MS LF
LS MF
MS LF
MS HF
MS = medium speed
LF = low feed
MF = medium feed
HF = high feed
X = recommended
0 = acceptable
- = not recommended
SANDVIK COROMANT USER’S GUIDE - COMPOSITE SOLUTIONS 58