USE OF Virgin PTFE DIAPHRAGM:
When the PTFE diaphragm (item 64) is
required, an outer plate (item 63) and inner
plate (item 66) must be used to plug the
diaphragm’s center hole. Sandwich the PTFE
and elastomeric diaphragms as shown. Torque
the outer plate to the hex nut (item 68), utilizing
the lock washer (item 67). Torque at 40 ft/lbs
(54.23 Newton meters). Fill the fluid cell as
specified in the DIAPHRAGM SERVICING
section of this manual. Note: Use only 2800 ml.
driver fluid when using PTFE. See DIAPHRAGM
SERVICING.