Specifications

Frequency range 100kHz(MAX)
Recorded channels
Ch1&Ch2 (Max.100kHz),Recording of single channel is not possible.
2GB: Approx. 33 minutes
(Ch1 and Ch2 at 100kHz)
Recording format ORF
Max. recordable memory capacity
2GB (in a CF card slot)
ORF
FFT analysis is possible at recording frequency range or lower.
200 data items, 10 record data items
(depending on the CF card capacity)
Analysis data can be saved simultaneously with three different formats:
DAT, TXT and BMP(TXT and BMP selectable).
10 types
Memorizes parameters which can reproduce all software and
hardware settings in the panel condition memory mode.
200 data items or less (depending on the CF card capacity)
200 data items or less (depending on the CF card capacity)
Main unit built-in memory (fixed) or CF card can be selected.
Main unit built-in memory x1 (Cannot be replaced by user)
Card slot (CF card) x1
When LED (green) is lit, insertion or
removal of memory card is inhibited.
Data record
Data file
File format
Panel condition memory
Contents of panel
condition memory
Voice memo memory
Handwritten memo memory
Recording device
6.Memory Functions
Recording time
Event mark number
Record number
Arbitrary numbering by [MARK] button operation
Automatic numbering by main unit start/stop operation
Off-line analysis
CF card insertion/
removal warning LED
14
Number of connectors
Maximum output
Impedance
Voice memo
Connector
Output adjustment
Number of ports
Standard
USB (type A)
DATA (mini B type)
1
100mW or more
Play back
Accepts φ=3.5 stereo mini jack (L)
By software
2
USB Ver.1.1/2.0(High Speed)
For USB1.1 printer/USB memory
For USB2.0 USB node function
7.Output Functions
Interface
External SPEAKER output
USB
Printer interface
Device
Number of connectors
Output voltage
Impedance
Source
Connector
Accepts thermal printers of recommended model
On-line data
Saved data
2
1Vrms F.S. ±1% for input voltage range F.S. (1kHz sine wave, 1MΩ load)
Approx. 33Ω
Input signal (after analog filtering)
φ=2.5 monaural jack
USB
Each connector outputs Ch1 or Ch2 data
Printer output
Source
Monitor output
Max. recordable
memory capacity
List display of condition settings
Can be saved in the XML (Text) format of condition.
9.Miscellaneous Functions
Condition view
Date (year, month, day) and time (hour, minute, second)
Can be turned on or off (in conjunction with ON
OFF of warning beep)
Can be turned on or off (in conjunction with ON/OFF of operation beep)
Clock
Operation beep
Warning beep
Harmonic
distortion
Frequency range
Output ON/OFF
Output
waveform
Spectrum flatness
Crest factor
Analysis frame length
Zoom mode analysis
Pink filter
0.1mHz to 100kHz (sine wave)
Band limiting not possible
-70dB or less
Prescribed with 1V
0
-p amplitude value
Turned on or off with the SIGNAL OUT button(Turned off at the time of activation)
ON/OFF for each button
ON
OFF
Sine wave
Swept sine
Pseudo random
Random
Impulse
256 to 4096
Possible for all waveforms
±1.0dB or less
±0.2dB or less
Sine wave
Swept sine
Pseudo random
Random
Impulse
Analog filter: -3dB/oct ±1.0dB (prescribed for 20Hz to 20kHz)
LED goes on when ON.
LED goes off when OFF.
20kHz−100kHz
0−20kHz
About 1.41
About 1.4 to 1.6
3.3 or less
3.3 or less
32.0 or less
Number of channels
Output connector
D/A converter
Maximum output voltage
Amplitude resolution
Offset resolution
Output format
Protection circuit
Isolation
Output current
1
BNC (C02 type)
16 bits
±10V (Amplitude + DC offset)
Approx. 2.5mV
Approx. 5mV
Unbalanced output
Short-circuit protection
No isolation
50Ω
Continuous
The output can be gradually increased or
decreased when the signal is turned on or off.
Taper rising time
Taper falling time
No isolation between chassis and digital common
Low impedance output (unbalanced)
±10
1ms to 32s (in 1-ms steps)
1ms to 32s (in 1-ms steps)
Can be set from 1 to 32767 in 1-cycle steps
Interval 62.5μs to 524s (Can be set in 62.5-μs steps)
Single-shot
Continuous
Time setup is possible.
8.Signal Output (CF-0771) ― Option
Output impedance
Output mode
Taper function
Burst
50mA (If 10mA is exceeded, harmonic distortion,
flatness, and crest factor are not prescribed.)
10.General Specifications
Power requirement  Input voltage 10.5 to 16.5VDC
Power connector    
DC jack (EIAJ TYPE5) Outer side: Negative electrode, Inner side: Positive electrode
Power consumption
Operating temperature range
Storage temperature range
Functional grounding terminal
     
Suspension of chassis 
VESA standard 100 x 100 (mm)/Can be suspended by attaching a φ5 adapter
Stylus pen   Can be stored in the main unit (accessory)
Carrying handle position 
(top level position)/30°/6/90°/110°/130°/180° (bottom level position)
           Forced-air cooling by an electric fan
           
Operating
noise
32.5dB(A) (Reference value)
Weight       Approx. 3.5kg/Approx. 4.8kg (battery pack mounted)
Main unit cooling
11.AC Adapter (SQ60W15P-03) 12.Battery Pack (CF-0792)
Input voltage 100 to 240VAC
Input frequency 50/60Hz
Output voltage Rating 15V
Output current Rating 4A
Safety standard Electrical Safety Law/CE/UL
Battery Lithium ion secondary battery
Shape Fixed to the rear section of the main unit (detachable)
Operating time
Minimum remaining battery level
Displays a warning message and shuts down automatically.
Charge Charged by the AC adapter when the main unit power is OFF.
Charge time About 8 hours (power OFF)
Remaining battery
level display
About 60 VA (AC adapter used)   
0 to +40
-10 to +50(including an external secondary battery)
Grounding terminal for noise elimination
Outside dimensions (not including
the handle and protrusions)
Displays the remaining battery level when operating on the secondary battery
4-level display.
Operates for 4 hours under standard operating conditions (2ch FFT analysis/
Signal output option not mounted/25 room temperature with a new battery
328mm(W) x 246mm(D) x 88mm(H) (battery not mounted)/328mm(W) x 246mm(D) x
120mm(H) (battery mounted)/Refer to outer dimensions for details