User Manual
TriFlash with SD Interface Product Manual (Preliminary), Rev. 1.2 © 2002/2003 SANDISK CORPORATION
2-1
2. Product Specifications
For the specifications in the following sections, values are defined at ambient temperature and nominal supply
voltage unless otherwise stated.
2.1. System Environmental Specifications
Table 2-1. System Environmental Specifications
Temperature Operating:
Non-Operating:
-25° C to 85° C
-40° C to 85° C
Humidity Operating:
Non-Operating:
8% to 95%, non-condensing
8% to 95%, non-condensing
ESD Protection ± 2kV, Human body model
Vibration Operating:
Non-Operating:
15 G peak to peak max.
15 G peak to peak max.
Shock Operating:
Non-Operating:
1,000 G max.
1,000 G max.
Altitude (relative to sea level) Operating:
Non-Operating:
80,000 feet max.
80,000 feet max.
2.2. Typical Power Requirements
Table 2-2. Power Requirements
VDD (ripple: max, 60 mV peak to peak) 2.7 V—3.6 V
(Ta = -25 – 85C)
@ VDD = 2.7V @ VDD = 3.6V
Operating current (maximum rates)
Fclk = 25 MHz, 0.5 Mbyte/s
Read/Write speed
Read: 30 mA
Write: 35 mA
Read: 40 mA
Write: 45 mA
(Ta = -25 – 85C)
Typical Maximum
@ 2.7 V 40 uA 120 uA
Sleep Current
@3.3 V 50 uA 150 uA