Instruction manual
SandenHeatPump–InstallationManual
Page16of26
MaintenanceMode
Maintenance mode is a function to check the heat pump unit status and to check and
perform other settings. It should generally be assumed that the owner does not operate
this function. The following modes can be found in the maintenance mode.
Blockout time setting mode
Set the block out time.
Error history display mode
Check the history of any errors that may have occurred.
Parameter display mode
Check the values measured by the thermistor.
Drive setting mode: Switch the heat pump unit on/off.
Compulsory operation mode: Compulsorily operate the water heating cycle.
Pump remote operation mode: Run the water circulation pump.
HowtoswitchtoMaintenanceMode
Press and hold down Up and Down keys together in the clock display mode to go to the
maintenance mode. After the mode is switched, press the Enter key to select a mode from
the six modes described above. To finish the maintenance mode, press and hold down
the Enter key, or leave for more than 60 seconds with no panel operation.
Change: Hold down ‘Up’ and ‘Down’; No operation for 60 seconds (delete min.?) – this change needs to
be done in three places.
Figure 13 Maintenance mode diagram
Dis
p
la
y
Slee
p
Mode
ClockDisplayMode
ClockSettingMode
ErrorHistor
y
Dis
p
la
y
Mode
ParameterDis
p
la
y
Mode
BlockoutTimeSettin
g
Mode
DriveSettin
g
Mode
Com
p
ulsor
y
O
p
erationMode
Enter
Enter
Enter
Enter
Enter
Enter
AnyKey
Enter
Enter
or
NoOperation
for60secmin.
NoOperation
for60secmin.
Holddown“UP”
and“DOWN”
tth
Enter
or
NoOperation
for60secmin.
PumpRemoteOperationMode