Assembly and Installation Instructions
Page 3/4
AUTO Mode
Manual
Override
Mode
Manual Override Operation Diagram
Turn wall switch OFF-ON 
in 3 Seconds
Turn wall switch OFF-ON 
in 3 Seconds again
FIG.1
CUSTOMIZATION OPTIONS:
FIG.2 
Shut-off Delay
The Shut-off delay is the length of time the light will stay at high-level brightness after motion has ceased 
to be detected. This Shut-off delay can be set when operation is in 3, 6 or 0 Mode by using the “TIME” 
knob located on the left side of the panel at the back the sensor lens (See Fig.2) . To increase 
the shut-off delay, turn the knob clockwise. To decrease shut off delay, turn the knob counterclockwise. 
The delay may be adjusted from a minimum of 5 seconds to a maximum of 3 minutes. The light will stay 
on as long as motion is detected continuously and will automatically turn to low-level brightness when no 
more motion is detected after the delay time has passed.
Sensitivity of Motion Sensor
The sensitivity of the motion sensor can be adjusted by using the “Sens” knob located on the right side of the panel at
the back of sensor lens (See Fig.2). To increase sensitivity, turn the knob clockwise. To decrease sensitivity, turn the 
knob counterclockwise. The sensitivity may be adjusted from a minimum of 5 feet to a maximum of 40 feet. 
Troubleshooting
---The light does not come on at all:
1. Make sure the wall switch and circuit breaker are on.
2. Make sure the wiring is correct.
3. Make sure the bulb is not burned out.
4. Cover the sensor with your palm to verify that the ambient light level is not too high.
----In Test Mode, the light stays on full brightness after 5 seconds:
1. If during daytime, make sure the slide switch is at the TEST position.
2. Whether the motion is detected at all time.
On the back of the sensor
Sensor Head
Time Low Level
Sens
Test
3H
6H
0
Time Low Level
Sens
Test
3H
6H
0
NOTE:
2. The sensitivity of the motion sensor will increase as the
1. Rotate the sensor head counterclockwise for adjusting settings
 by hand and then rotate the sensor head clockwise back after 
 the settings have been adjusted. (Fig.3)
 environmental temperature gets cooler. For best performance,
 gently clean the lens with a soft cloth every 1 or 2 months to 
 assure maximum sensitivity.
3. For best performance, install fixture at least 6 feet above
 the ground. At such a height, the fixture will provide a
 detection distance of up to 40 feet at 77 degrees
 Fahrenheit. (See Fig.4)
4.The sensor detects across a detection range of 180 degrees.
 (See Fig.5) 
5. The sensor will be more sensitive to motion across its
 detection path than motion directly towards it. (See Fig.6) 
5`
6`
10`
40`
Where you install your lantern is important:
Be sure the light is mounted straight on the wall;
otherwise, the detection distance may be limited. 
Fig. 4 Fig. 5
Fig. 3
180˚
6. To reduce possible nuisances, do not mount the fixture 
 near a heat source like an air conditioner, vent or furnace
 exhaust, or in a direction facing any reflecting object or
 other light source. 
Motion
Least sensitive
Motion
Most sensitive
Sensor
Fig. 6
Sens
Level
6H
0
3H