Specifications

OWNER’S GUIDE  INTERFACE CARDS | 18435
up to 256 times over sample clock used for these types of analog to digital converters. For this purpose the
DEWE-CLOCK is equipped with a RJ45 connector for connection to the DEWETRON data acquisition sys-
tem. A standard CAT5e or CAT6 Ethernet cable with up to 30 m can be used for connection.
Please note: also the data acquisition has to be provided ORION-DSA-SYNC option for having access to the
synch bus of the board.
Congure of DS-7 Software
To unlock the GPS functionality in DS-7 software, the GPS has to be congured in the Hardware Setup
screen (Settings > Hardware Settings > GPS):
Select “DEWESoft USB” from the GPS device dropdown menu.
DS-7 will automatically start searching for a connected device.
There are only a few settings on this screen, as follows:
Update rate
The update rate is xed at 1 Hz.