Specifications
OWNER’S GUIDE IMPORTANT ACCESSORIES | 10269
MOB-DISP-17 Specications
Parameter MOB-DISP-17
Description 17” Ruggedized video display, suitable for mobile applications
Power requirements 12VDC, 5A peak. External AC/DC adapter included
Power input connector LEMO FGG.1B.302.CLA
Screen resolution SXGA (1280 x 1024 pixels) resolution, Low power consumption
Backlight 90 LEDs
TFT details
Pixel pitch: 0.264(H) x 0.264(W) mm
Active display area: 337.92(H) x 270.336(V) mm
Surface treatment: Haze 25%, Hard-coating (3H)
Display colors: 16.7M (Hi-FRC)
Pixel arrangement: RGB vertical stripe
White luminance: 360(Typ.) cd/m2
DIsplay OEM Based on the Samsung LTM170ET01 TFT display with LED backlight unit
Touchscreen Capacitive touchscreen included, with USB 2.0 interface and drivers for Windows 7
Mounting positions
VESA 100 tapped holes on the side opposite the display, and
#1/4-20 tapped holes on top and bottom for suction cup mounting
Standard accessories
1m VGA cable with DVI adapter
2.5 m USB cable
1 m power cable, FGG.1B.302.CLA LEMO to banana plugs
AC/DC adapter for lab usage
Optional accessories (DISP-17-OPT)
2 high-grade suction cups
3 m VGA cable
3 m USB cable
1 m power cable (LEMO to cigarette lighter plug)
USB convenience jacks
Three (3) USB 2.0 (type A) convenience jacks. Requires that the USB 2.0 (type B) input jack be
connected to the DEWE system’s USB 2.0 interface via a standard USB 2.0 A to B type cable (one is
included)
Environmental
Operating temperature: 0 °C to 50 °C, 95% RH
Center of glass surface temperature absolute max: -10 °C to +60 °C
Storage temperature: -25 °C to 70 °C, 70% RH (do not store in direct sunlight)
Dimensions: (W x D x H): 384 x 39 x 337 mm (15.1 x 1.53 x 13.27 in.)
Weight: 4.5 kg (10 lbs), not including cables
MOB-DISP-17 Safety Notices
Storage
⇒ (a) Do not leave the MOB-DISP-17 in high temperature, and high humidity for a long time. It is highly recom-
mended to store the Module with temperature from 0 to 35°C and relative humidity of less than 70%.
⇒ (b) Do not store the MOB-DISP-17 Module in direct sunlight.
⇒ (c) The MOB-DISP-17 should be stored in a dark place. It is prohibited to apply sunlight or uorescent light in
storing.
Operation
⇒ (a) Do not connect or disconnect the Module in the “Power On” condition.
⇒ (b) Power supply should always be turned on/o by the item 6.3 “Power on/o sequence”