Input specifications DEWE-3050 - DAQ version DEWE-3050 - MDAQ version
Slots for DAQ or PAD modules 16 or 32 --
MDAQ-SUB positions When 16 DAQ slots are installed, up to 64 more channels
of MDAQ can be added to the system, for 80 channels
total.
Consult Dewetron for configuration assistance.
Up to 6 x 2.0U MDAQ-DSUB (96 channels) or 8 x 1.5U
MDAQ-BNC (128 channels) can be installed. Also many
combinations of MDAQ and other panels are possible.
Consult Dewetron for configuration.
Main system
Total PCI slots 5 x full-length PCI slots (one is used by the standard A/D card)
Hard disk C: 100 GB removable C drive / 500 GB removable D drive (optional solid state drive)
Data throughput to disk 80 MB/s typical; faster rates available with the additional of an internal RAID controller and/or additional drives
Power supply 120/240 VAC, 50/60 Hz AC mains power.
Battery power Includes standard UPS with four hot-swappable SideHAND2 series batteries. Batteries are charged automatically
when AC power is connected.
Display 17” SXGA display, 1280 x 1024 px, with resistive touchscreen. Display is removable, and can be mounted backwards
when not in use.
Processor Intel 8-core i7 2.0 GHz CPU, on a standard ATX mainboard
RAM 4 GB standard
Ethernet 3 x ethernet interfaces standard (1 Gb)
USB Four x USB 2.0 interfaces available
RS232 One serial interface on a DB9 connector available
Operating system Microsoft Windows7 32-bit included (upgrades to 64-bit will be available Summer 2013)
Dimensions (W x D x H) 425 x 340 x 191 mm (16.7 x 13.4 x 7.5 in.)
Weight 12 kg typical (26.4 lbs)
Free PCI slots 4 (the standard ORION-1616-100 A/D card uses one of the PCI slots)
Environmental specifications
Operating temperature -20 to 50C (0 to 45C with batteries installed) (storage temp -20 to 60C)
Humdity 10 to 80% non-condensing, 5 to 95% relative humidity
Vibration MIL-STD-810F, EN 60068-2-6, EN 60721-3-2 class 2M2
Shock MIL-STD-810F, EN 60068-2-27
Required to complete this model
Conditioners: Any 16 or 32 DAQ series plugin modules Up to 128 MDAQ series channels
A/D card(s) The ORION-1616-100 is included as standard. You may upgrade this card as follows:
UP-ORION-16-22 upgrade the resolution to 22-bits, add antialiasing filters (AAF), max. SR remains at 100
kS/s/ch
UP-ORION-16-24 upgrade the resolution to 24-bits, add AAF, max. SR increases to 200 kS/s/ch
UP-ORION-16-22-32 upgrade the resolution to 22-bits, add AAF, increase from 16 to 32 analog channels
UP-ORION-100-1000 upgrade the max. SR to 1000 kS/s/ch
UP-ORION-100-200-8 upgrade the resolution to 24-bits, add AAF, max.SR increases to 200 kS/s/ch, decrease to
8 channels
UP-ORION-100-1000-8 upgrade the max. SR to 1000 kS/s/ch, decrease to 8 channels
Software DS-7-SE data acquisition software is included as standard*
32 analog channels, or multiple video cameras, or DEWE-CAM-FW-70, or DEWE-CLOCK use requires upgrade to
PROF edition.
64+ analog channels requires upgrade to DSA edition.
LabVIEW VIs are available for Dewetron ORION series A/D cards and DAQ series signal conditioners.
Popular upgrades
Counter expansion (UP-ORION-CTR8) Upgrades the A/D card from 8 TTL digital I/Os and 2 TTL counter / encoders to:
8 synchronous TTL digital inputs protected up to 25 VDC
8 synchronous counter / encoder or 24 digital inputs with programmable threshold levels (0-40 V), input voltage range
-35 to 60 V, AC/DC coupling
Includes DB37 pin connectors installed
Synchronization interface (UP-ORION-SYNC) Installs the SYNC hardware input/output ports and LED indicators onto the mainframe. Allows systems with the same
base ORION card to be synced. Additionally Requires DS-OPT-NET software option for synchronization under DS-7
software.