Specifications
5-100 | OWNER’S GUIDE
Counter/Encoder Specications
Parameter DEWE-3210 series DEWE-3211 series DEWE-3213 series
Number of counter channels According to the A/D card installed (see tables) 8
Counter modes ORION cards: Event counting, waveform timing, encoder, tacho, geartooth sensor
AD series cards: Event counting, waveform timing, tacho
Counter input signal level Standard: TTL level
Optional: user adjustable trigger level (when ORION
cards whose model names end in 4 or 5 are ordered.
See A/D card tables)
Standard: TTL level
Counter input connectors Standard: Two LEMO connectors on the left side panel,
one for each counter input
Optional: More LEMO connectors, or alternative
connectors, for the counters
Standard: Eight LEMO
connectors
Number of Digital input/outputs According to the A/D card installed (see tables) 24 digital inputs
Digital input signal level Standard: TTL, non-isolated
Optional: Wider range, isolated digital input
According to the A/D card installed (see tables)
TTL level, non-isolated
Digital input connector DSUB37 connector on the left side panel, which has the
digital I/O lines, counter, and trigger line from the first
installed A/D card.
Each of the 8 LEMOs has
three digital inputs
CAN BUS Specications
Parameter DEWE-3210 series DEWE-3211 series DEWE-3213 series
Number of CAN bus interfaces According to the A/D card installed (see tables below) 2 x high speed CAN ports
Interface type CAN 2.0B, up to 1 MBit/sec
Special protocols supported J1939 (standard)
OBDII PLUGIN-OBDII option)
CAN output (DEWESoft-OPT-CAN option)
Isolation not isolated, however, CAN-OPT-ISO adapters are available optionally, which will
isolated the CAN BUS interfaces.