Technical data

Electrical Characteristics
MCIMX31C/MCIMX31LC Technical Data, Rev. 4.3
Freescale Semiconductor 77
IP56 Controls setup time for write Tdcsw Tdicuw–1.5 Tdicuw ns
IP57 Controls hold time for write Tdchw Tdicpw–Tdicdw–1.5 Tdicpw–Tdicdw ns
IP58 Slave device data delay
8
Tracc 0 Tdrp
9
–Tlbd
10
–Tdicur–1.5 ns
IP59 Slave device data hold time
8
Troh Tdrp–Tlbd–Tdicdr+1.5 Tdicpr–Tdicdr–1.5 ns
IP60 Write data setup time Tds Tdicdw–1.5 Tdicdw ns
IP61 Write data hold time Tdh Tdicpw–Tdicdw–1.5 Tdicpw–Tdicdw ns
IP62 Read period
2
Tdicpr Tdicpr–1.5 Tdicpr Tdicpr+1.5 ns
IP63 Write period
3
Tdicpw Tdicpw–1.5 Tdicpw Tdicpw+1.5 ns
IP64 Read down time
4
Tdicdr Tdicdr–1.5 Tdicdr Tdicdr+1.5 ns
IP65 Read up time
5
Tdicur Tdicur–1.5 Tdicur Tdicur+1.5 ns
IP66 Write down time
6
Tdicdw Tdicdw–1.5 Tdicdw Tdicdw+1.5 ns
IP67 Write up time
7
Tdicuw Tdicuw–1.5 Tdicuw Tdicuw+1.5 ns
IP68 Read time point
9
Tdrp Tdrp–1.5 Tdrp Tdrp+1.5 ns
1
The exact conditions have not been finalized, but will likely match the current customer requirement for their specific display. These
conditions may be device specific.
2
Display interface clock period value for read:
3
Display interface clock period value for write:
4
Display interface clock down time for read:
5
Display interface clock up time for read:
6
Display interface clock down time for write:
7
Display interface clock up time for write:
8
This parameter is a requirement to the display connected to the IPU.
9
Data read point:
10
Loopback delay Tlbd is the cumulative propagation delay of read controls and read data. It includes an IPU output delay, a
device-level output delay, board delays, a device-level input delay, an IPU input delay. This value is device specific.
Table 48. Asynchronous Serial Interface Timing Parameters—Access Level (continued)
ID Parameter Symbol Min. Typ.
1
Max. Units
Tdicpr T
HSP_CLK
ceil
DISP#_IF_CLK_PER_RD
HSP_CLK_PERIOD
----------------------------------------------------------------
=
Tdicpw T
HSP_CLK
ceil
DISP#_IF_CLK_PER_WR
HSP_CLK_PERIOD
------------------------------------------------------------------
=
Tdicdr
1
2
---
T
HSP_CLK
ceil
2 DISP#_IF_CLK_DOWN_RD
HSP_CLK_PERIOD
-------------------------------------------------------------------------------
=
Tdicur
1
2
---
T
HSP_CLK
ceil
2 DISP#_IF_CLK_UP_RD
HSP_CLK_PERIOD
--------------------------------------------------------------------
=
Tdicdw
1
2
---
T
HSP_CLK
ceil
2 DISP#_IF_CLK_DOWN_WR
HSP_CLK_PERIOD
---------------------------------------------------------------------------------
=
Tdicuw
1
2
---
T
HSP_CLK
ceil
2 DISP#_IF_CLK_UP_WR
HSP_CLK_PERIOD
----------------------------------------------------------------------
=
Tdrp T
HSP_CLK
ceil
DISP#_READ_EN
HSP_CLK_PERIOD
--------------------------------------------------
=