User guide
not registered in the user information instead of using multi-switch access type of
OfficeServ Link V3.
That is, this switch information is set to enable all application programs used in
OfficeServ Link V2 to be used in OfficeServ Link V3 (backward compatibility). When the
single switch application program that a user is not registered is connected to
OfficeServ Link V3, this basic switch information is provided and the messages between
application program and this basic switch are relayed.
<Figure 3–8 Basic Switch Information Selection >
Set a switch No. added to configure the communication environment as the basic
switch. If not, application program access may fail.
The information on the basic switch of each user is described in the user
information registration step.
The information on the basic switch of each user is prior to the basic switch in
the communication environment.
3.2.3 Communication Environment for User Access Standby
When the connection to the switch is successfully performed, the link program allows the
access of each user and perform task to provide required services. At the time, a user
access is performed through LAN based TCP / IP. The value of communication
environment for user access standby is used to set the port No. of each user access
request standby. 6000 is entered by default. If required, the value over 1024 can be
entered. The value ranging from 0 to 1023 is included for the services in OS.
Port No. may be used by another service of the system, and in this case, the No. cannot
be entered. The status of the ICT/IP port NO. being used in the system can be checked
through the following command (in the command prompt window).
Netstat –a –e –n –p TCP