User guide

COLOR CCD CAMERA User Guide
32
COLOR CCD CAMERA User Guide
33
PRIVACY : Mask an area you want to hide on the screen.
Operating Your Camera
- FILLSET : Fills in a selected MD area. The color of filling is sequentially selected as
brown, orange, blue, cyan, green, yellow, magenta and red.
- RETURN : Select this to save the MOTION DET menu settings and return to the
SPECIAL menu.
1) When the SPECIAL menu screen is displayed, press the Function Setup switch so that
the arrow indicates ‘PRIVACY’.
 2) Set up the mode using the Function Setup switch.
- AREA : You can select up to 12 PRIVACY areas.
- MODE : Determines whether to use the area selected in the AREA.
- MASK COLOR : Determine area color. You can select Green, Red, Blue, Black, White, Gray.
- MASK TONE : Adjust the brightness of MASK COLOR.
- TOP/BOTTOM/LEFT/RIGHT : Adjust the size and position of the selected area.
- RETURN : Select this to save the PRIVACY menu settings and return to the SPECIAL
menu.
COMM ADJ (Communication Adjustment) :
This function sets up the camera communication status when controlling the camera
through an external control device.
1) When the SPECIAL menu screen is displayed, press the Function Setup switch so that
the arrow indicates ‘COMM ADJ’.
 2) Set up the mode using the Function Setup switch.
PRIVACY AREA SETUP
1.AREA AREA1
2.MODE OFF
3.MASK COLOR GREEN
4.MASK TONE 1
5.TOP 39
6.BOTTOM 79
7.LEFT 13
8.RIGHT 52
9.RETURN
LANGUAGE : You can select the menu language according to your requirements.
RETURN : Select this to save the SPECIAL menu settings and return to the MAIN
SETUP menu.
- CAM ID : Determines the camera's identification number
(between 0 and 255).
- BAUD RATE : You can select 2400/4800/9600/19200/38
400/57600 bps.
- UART MODE : You can select NONE, EVEN or ODD for
the parity bits.
- RET PKT : Determines whether to send a command back
to the controller device when a communication
control command is sent to the camera.
- DISP ID : Display camera title on top left corner of the screen.
- PROTOCOL : Select the communication PROTOCOL.
(SAMSUNG-T, SAMSUNG-E, PELCO-D, PELCO-P, BOSCH, HONEYWELL, VICON and
PANASONIC)
- RETURN : Select this to save the PRIVACY menu settings and return to the SPECIAL menu.
* Initial value of communication adjustment
Item
Camera ID BAUD RATE UART MODE PET PKT
Initial value
1 9600 8-NONE-1 ENABLE
Select a desired EXIT mode using the Function Setup switch depending on the camera
purpose.
- SAVE : Save the current settings and exit the MAIN SETUP menu.
- NOT SAVE : Do not save the current settings and exit the MAIN SETUP menu.
- RESET : Resets the camera settings to the factory defaults. Communication,
Language and Monitor settings are not initialized.
EXIT
•
Asbelow,thenamesofprotocolhavebeenchanged.
-STW(SPD)SAMSUNG-T
-SECSAMSUNG-E
Notes