Specifications
CHAPTER 3. Specifications
3-2
© SAMSUNG Electronics Co., Ltd.
3.1.2 Environments
Table 3.3 Environments
Operating Temperature 32-104 °F/0-40 °C
Storage Temperature 13.1-158 °F/-10.5-70 °C
Humidity 10-90 % non-condensing
3.1.3 Cable Requirements
Table 3.4 Cable Requirements
EQUIPMENT CABLE AWG MAX FEET MAX METERS
Digital Keyset 1 PR. TWISTED 24 1300 400
Add-On Module 1 PR. TWISTED 24 1300 400
Single Line Station 1 PR. TWISTED 24 3000 1000
Door Phone 2 PR. TWISTED 24 330* 100
WBS24 2 PR. TWISTED 24 1300 400
Cable length
This is the maximum length of the cable between the door phone and the DPIM.
The DPIM can be installed up to 270 cable meters from the KSU.
3.1.4 System Tones
Table 3.5 System Tones
Tone Frequencies SVMi-8
Dial Tone 350 + 440 Hz Continuous
Ring Back Tone 440 + 480 Hz 1 sec on + 3 sec off
Busy Tone 480 + 620 Hz 0.5 sec on + 0.5 sec off
DND/No More Tone 480 + 620 Hz 0.25 sec on + 0.25 sec off
Error Tone 480 + 620 Hz 0.25 sec of each tone
Confirmation Tone 350 + 440 Hz Three bursts of tone 0.1 sec on + 0.1 sec
Transfer/CONF 350 + 440 Hz 0.1 sec on + 0.1 sec off
The details of system tones
The details of system tones may vary according to the specifications of each
country.